HP StorageWorks X5500 Network Storage Gateway for Linux setup guide (AP811-96003, October 2009)

SAN Switches. This is used to specify the hostnames or IP addresses of the Fibre Channel switches
that are directly connected to the nodes in the cluster. Click Add, and then specify the hostname or
IP address of the first Fibre Channel switch.
Repeat this procedure to specify the remaining Fibre Channel switches, including cascading switches.
SNMP Community String. The default SNMP community string for HP X5500 Storage Gateway for
Linux is private. If you want to use a custom community string, enter the appropriate value here.
The SNMP community string must be set to the same value on both HP X5500 Storage Gateway for
Linux and the SAN switches configured above.
When you have completed the SAN & Fencing tab, go to the Storage Settings tab.
Storage Settings tab
The Storage Settings tab allows you to select membership partitions and create a snapshot configuration
for taking hardware snapshots.
HP StorageWorks X5500 Network Storage Gateway for Linux setup guide 29