Network Storage Router e1200-160 - User Guide
Basic Troubleshooting
159Network Storage Router e1200-160
Verifying PRLI Data
The router returns the PRLI (preliminary login) response data as specified in
Table 12.
In the default configuration, the router returns PRLI Data (PRLI Accept Payload)
with the Target bit SET and the Initiator bit CLEAR. However, some
configurations require the Initiator bit be SET, such as in router-to-router
configurations. See the Fibre Channel Overrides Menu for more information
about changing the initiator bit.
Table 12: PRLI
Item Value
PRLI Command Code 0x20
Page Length 0x10
Payload Length 0x10
Type Code 0x8
Type Code Extension 0x0
OPA 0x0
RPA 0x0
IPE 0x1
Response Code 0x1
Originator Process Associator 0x0
Responder Process Associator 0x0
Initiator Function 0x1
Target Function 0x1
Command/Data Mixed Allowed 0x0
Data/Response Mixed Allowed 0x0
Read XFER_RDY Disabled 0x1
Write XFER_RDY Disabled 0x0