HP B-series Fabric OS 7.1.0c Release Notes (5697-2892, October 2013 - includes all 7.1.0x versions)

Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.When a switch is unreachable from Network Advisor, it
is displayed as an HP 4/8 or 4/16 SAN Switch regardless
of the actual switch type. Once the switch becomes
reachable, it displays correctly as the actual switch Type
in Network Advisor.
Fixed in Fabric OS 7.1.0.The systemverification on an HP SN3000B 16Gb
FC Switch runtime increased from 4 minutes in Fabric OS
7.0.1 to 29 minutes in Fabric OS 7.0.1b.
Fixed in Fabric OS 7.1.0.A switch panic occurs during HA Failover with Failed
expression: area ==
sw->sw_pt[port]->full_fmt_area
Fixed in Fabric OS 7.1.0.The perfttmon --delete -sconfig command does
not behave as expected on 16 Gb/s platforms.
Fixed in Fabric OS 7.1.0.The ABTS pattern command output does not match the man
page description.
Fixed in Fabric OS 7.1.0.Offline port FCID is not synced to the standby CP.
Fixed in Fabric OS 7.1.0.CRC errors occur on ports with LWL SFPs running at 8
Gb/s.
Fixed in Fabric OS 7.1.0.Busy buffer stuck cause blades to fault.
Workaround prior to upgrade:A fast FLOGI frame comes in before the port state has
changed to AC (Active online) and causes various switch
problems.
Perform a port disable and then port enable on
the problem port during the massive Nport FLOGI storm.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:FCIP OSTP can incorrectly hide device reservation conflict
status causing unusable tape devices.
Perform a port disable and then port enable on
the impacted device ports, or reboot the tape device(s).
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Crypto Target Container (CTC) is not ready for operation
after an HP Encryption SAN Switch panic reboot.
Fixed in Fabric OS 7.1.0.Configdefault does not change the link cost in a logical
switch.
Workaround prior to upgrade:Detected termination of Name Server Daemon (NSD)
during CLI nodefind execution.
Avoid executing the nodefind CLI command under the
noted conditions.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.The "CustomizeColumns" tab under "SwitchEvents" have
three greyed out options in Webtools.
Workaround prior to upgrade:An SW.mib syntax error prevents loading in HP NNMi
9.10 patch 2.
Manually edit the SW.mib file.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:A Fabric OS memory leak is triggered through Storage
Application Services with a misconfigured zone.
Remove the frame redirect and recreate the binding.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Running the perfcfgrestore command after the
perfcfgsave command may not restore all
PerfEEMonitors.
Fabric OS 7.1.0 fixes 61