HP B-series Fabric OS 7.1.0c Release Notes (5697-2892, October 2013 - includes all 7.1.0x versions)

Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Workaround prior to upgrade:The PortPerfShow command is showing bandwidth
utilization being reported as 0.
Perform an HA Failover.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Some SNMP MIBs such as swCpuAction and swMemAction
are not accurate.
Fixed in Fabric OS 7.1.0.The LED behavior of HP SN3000B 16Gb FC Switch FAN
FRU does not match what is documented in the hardware
manual.
Fixed in Fabric OS 7.1.0.The fmmonitor --clear command does not properly
clear the Count value.
Fixed in Fabric OS 7.1.0.The IP address is not included in agshow on a switch in
AG mode using IPv6.
Fixed in Fabric OS 7.1.0.The weblinker file descriptor on the CEE platform leaks
when monitored by Network Advisor.
Fixed in Fabric OS 7.1.0.Selected switch configurations are accessible without
authenticating.
Fixed in Fabric OS 7.1.0.The HP DC SAN Director Multiprotocol Extension Blade
DP 1 Soft Faults due to DP Panic.
Fixed in Fabric OS 7.1.0.The HP DC SAN Backbone Director root file system may
be exported during a security scan using "nessus" auditing
software.
Fixed in Fabric OS 7.1.0.Disk replication fails when response to RNID is discarded.
Fixed in Fabric OS 7.1.0.Unable to remove the fmmonitor that has been added to
port 0 with the default Frame Type (SCSI).
Fixed in Fabric OS 7.1.0.When there is a race condition between the fabric watch
and environment monitor modules during bootup, fabric
watch could get stale information and falsely identify a
power supply that is not there.
Workaround prior to upgrade:With In Order Delivery set, using port mirroring to view
traffic causes the switch traffic to stop.
HA Failover will resume traffic.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.The fmmonitor create command returns an undefined
error code when trying to create the 42nd monitor rather
than returning "Maximum no of monitors reached”.
Fixed in Fabric OS 7.1.0.The discard C3 counter does not match the sum of the
registers it represents.
Fixed in Fabric OS 7.1.0.The thconfig --show filter command shows that
there are 51areas, (9defaults, 41user-defined, and 1
perfPT), even though the max frame_type is 50.
Fixed in Fabric OS 7.1.0.Interface flowcontrol change modifies the running config,
but the interface stats do not show the change.
Fixed in Fabric OS 7.1.0.On encryption platforms, a high frequency of Test Unit
Ready (TUR) etc., commands result in DataBase out of sync.
Fixed in Fabric OS 7.1.0.The perfttmon --show [number of flows]
command does not show expected results.
Fabric OS 7.1.0 fixes 57