HP B-series Fabric OS 7.1.0c Release Notes (5697-2892, October 2013 - includes all 7.1.0x versions)
Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.FICON Emulation incorrectly generates LBY in response to
an unsolicited status from an alias device.
Fixed in Fabric OS 7.1.0.There is a slow response to VLAN requests from the CNA
on an HP 2408 FCoE Converged Network Switch.
Fixed in Fabric OS 7.1.0.Various man pages are lacking specific details.
Fixed in Fabric OS 7.1.0.Several FICON IFCCs are reported during initial online
processing.
Fixed in Fabric OS 7.1.0.Non-FC ports do not support media validated against OUI.
Workaround prior to upgrade:The show process cpu summary output does not match the
current cpu utilization or load.
Top and upload at the Fabric OS interface shows the
proper data.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:SFP shows "No Module" on switches during a failover test
when connected through DWDM.
Disable and re-enable the ports.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Performance issues occur on a compressed FCIP tunnel
when running Fabric OS 7.0.1a compared to Fabric OS
6.4.2.
Fixed in Fabric OS 7.1.0.Man pages for islshow and fdmishow are inconsistent
with intended functionality.
Fixed in Fabric OS 7.1.0.Port Fencing raslog message FW- 1202 FW-1501 severity
needs to be upgraded from Warning to Error.
Fixed in Fabric OS 7.1.0.SW-MIB files do not load into the MIB Browser because a
tab is being used instead of a space.
Fixed in Fabric OS 7.1.0.Performing switchdisable, configdefault,
portcfgpersistenetenable, portcfgdefault,
then portcfgpersistent enable can cause some
ports to stay in "FC Disabled" state.
Workaround prior to upgrade:When issuing the statsclear command it will return
the error that slot0 is non-existent in Fabric OS 7.0.1a.
Use the slotstatsclear command instead of
statsclear.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Soft parity errors are causing disruption on the HP
Encryption SAN switch and the HP DC Switch Encryption
FC Blade.
Fixed in Fabric OS 7.1.0.Target device operating at 8 Gb/s fails to gain connectivity
to the HP SN8000B SAN Directors.
Fixed in Fabric OS 7.1.0.Results of a slotshow command reports a software faulted
CP as enabled despite being halted as a result of rebooting
five times.
Fixed in Fabric OS 7.1.0.The Webtools throughput utilization graph does not match
portperfshow output.
Fixed in Fabric OS 7.1.0.There is a large number of CRC with good EOF errors on
the HP DC SAN Backbone Directors when an HP DC SAN
Director 64-port 8Gb FC Blade is installed in slots 1,3,9.
56