HP B-series Fabric OS 7.1.0c Release Notes (5697-2892, October 2013 - includes all 7.1.0x versions)

Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.The Nameserver is returning the wrong value for GFF_ID
(0x01F).
Fixed in Fabric OS 7.1.0.OUI information changed for a specific OEM.
Fixed in Fabric OS 7.1.0.In NPIV setup, perfttmon only displays ingress values
even when egress is selected.
Fixed in Fabric OS 7.1.0.Embedded platform with internal CU port connected to an
HBA turns into a G-Port.
Fixed in Fabric OS 7.1.0.During zone rename, when a new zone name is added in
the list and then removed, the old zone name causes a
switch panic.
Fixed in Fabric OS 7.1.0.Even thought static routes are not supported in Fabric
OS7.0, 'uRoute' commands are still present.
Fixed in Fabric OS 7.1.0.Starting with Fabric OS 6.3.x, there is unexpected NTP
behavior.
Fixed in Fabric OS 7.1.0.The CVLC daemon terminates as a result of processing
large encryption configuration (8K-9K Initiator Target
LUNs).
Fixed in Fabric OS 7.1.0.Users will get a FICON keepalive timeout on an HP 1606
SAN Extension Switch if there is not enough bandwidth
on the FCIP tunnel.
Workaround prior to upgrade:A switch upgrade from Fabric OS 6.3.x to 6.4.x in
IM2/IM3 mode causes zone daemon memory space
overrun.
Perform a HA Failover when the firmware is completely
upgraded.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:The WWN of an HBA connected to a switch running in
AG mode does not show up on the zoning admin windows.
Use CLI to manually configure zoning.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.After changing F-port buffers on an HP 1606 SAN
Extension Switch via WebTools, the switch cannot set
buffers back to the default setting of 8.
Fixed in Fabric OS 7.1.0.The seccertutil command fails to download certificates
from an ftp server if the password ends with an exclamation
mark (!).
Workaround prior to upgrade:Performing an upgrade on an HP DC SAN Backbone
Director from Fabric OS 6.4.1a to 6.4.2b results in many
ports at "Not ready for F or L ports".
Manually rebuild fabric by bouncing the E_port or perform
a switch disble/enable.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:The HP DC SAN Backbone Director with an HP DC Switch
Encryption FC Blade reports FSS error in the RAS log after
a cryptocfg --commit command.
Reboot the standby CP.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.A switch panic occurs when users enter an index range
with a larger value than is present using the portname
-i -f command.
Fixed in Fabric OS 7.1.0.WebTools are considered an untrusted application.
54