HP B-series Fabric OS 7.1.0c Release Notes (5697-2892, October 2013 - includes all 7.1.0x versions)

Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.The HP SN8000B 4-Slot SAN Director Switch panics during
systemverification when it is run repeatedly.
Workaround prior to upgrade:On 16 Gb/s platforms, a port is negotiating to 16 Gb/s
even though the optic is only capable of 8 Gb/s speeds.
Bounce the problem port with this kind of mismatch speed
setting.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.All clear text and encrypted LUN states are unavailable.
Fixed in Fabric OS 7.1.0.If NPIV was disabled on FCoE ports prior to upgrading to
Fabric OS 7.0, NPIV cannot be enabled on those FCoE
ports.
Workaround prior to upgrade:The NS contains stale entries after a bad disk is removed
from a loop attached device.
Bounce the port where the device is connected.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:Access Gateway crashes upon receiving bad frame(s) from
devices.
Avoid sending LOGO with SID 0 to AG.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:If HP DC SAN Director Multiprotocol Extension Blades are
swapped, the Inband Mgmt configuration is not properly
loaded onto the new blade.
Reboot the CP.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.CR8 blade in HP DC SAN Backbone Director went offline,
but routes are not removed if the PCI scan finds an
inconsistency in the power state of a blade.
Workaround prior to upgrade:Cannot remove configured Admin Domain if defzone is
configured as "allaccess".
Remove the zone files from switch and reboot.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Device returning more RRDYs than it is supposed to,
causing the TX credit of the switch to increase beyond the
initially negotiated value, which results in more frames
TXed to the device.
Fixed in Fabric OS 7.1.0.Msd is not freeing resources after RPL/DPL queries and
may cause switch panic or failover.
Fixed in Fabric OS 7.1.0.The HP 2408 FCoE Converged Network Switch running
Fabric OS 6.4.2 does not display LLDP neighbor Port
Description when interoperating with another vendor's
switch.
Fixed in Fabric OS 7.1.0.When multiple Network Advisor sessions request license
details from the switch, requests may fail.
Fixed in Fabric OS 7.1.0.The Encryption Engine does not handle Logout Extended
Link with Initiator correctly.
Fixed in Fabric OS 7.1.0.An FSPF error message appears when the CEC POR is
started, but does not appear in the errdumpall output.
Workaround prior to upgrade:An FCIP Tunnel in an FCR Backbone may lose buffer credits
and go down if FastWrite is enabled.
Disable FCIP FastWrite.
Fixed in Fabric OS 7.1.0.
Fabric OS 7.1.0 fixes 47