HP B-series Fabric OS 7.1.0c Release Notes (5697-2892, October 2013 - includes all 7.1.0x versions)

Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.After FCIP links in an FCR backbone fabric bounce several
times, FCR no longer translates all SID/DIDs properly.
Workaround prior to upgrade:DP panicked after modifying metric on FCIP Circuit using
a crossport with IPSec enabled.
Disable IPsec on the FCIP tunnel.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.In a FICON environment the active configuration is out of
synchronization with Fabric OS, indicating a port is
blocked after an HA Failover.
Fixed in Fabric OS 7.1.0.The HP Encryption SAN Switch is set to faulty, due to I/O
sizes greater than 512 KB starting at LBA 0 for an
encrypted LUN.
Fixed in Fabric OS 7.1.0.The portcfgshow command displays incorrect values
for "Fill Word (Current)" field.
Fixed in Fabric OS 7.1.0.TopTalker Monitor fails if user changes the monitor from
Egress to Ingress.
Fixed in Fabric OS 7.1.0.If users disable multiple circuits in an FCIP tunnel, traffic
may not be evenly distributed across remaining circuits.
Fixed in Fabric OS 7.1.0.There is a pdmd memory increase detected on the standby
CP of an HP SN8000B 8-Slot SAN Backbone Director with
max LS creation and fully populated EX-Ports after a long
period of time with I/O running.
Workaround prior to upgrade:FICON Tape Pipelining Channel aborts I/O after
presenting pending Attention status.
Disable FICON Tape pipelining.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:A port is segmented and the error “FABR-1001, 1 of 8”
trunks failed authentication during portenable of a port
range.
Disable and enable the segmented port.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:Access Gateway N-port is stuck in G-port after a firmware
upgrade with QoS enabled on the attached fabric switch.
Disable QoS on the Fabric switch for the impacted link.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Unable to configure ports as extended distance using CLI
on the HP SN6000B 16Gb FC Switch 10G ports without
the Extended Fabric license. Users should be able to
configure any non-default Extended Fabric mode on a
licensed 10G FC port without requiring the Extended Fabric
license.
Workaround prior to upgrade:D-port tests fail on some ports when run on more than four
links simultaneously.
Toggle the port(s).
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:Encrypted I/O halts when the initiator is configured for a
frame size of 512 kb.
Configure HBAs with 2112 frame size.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:There is a failed login attempt after a reboot from
firmwaredownload, causing a fwd panic.
Wait 1 minute after reboot before trying to log in.
Fixed in Fabric OS 7.1.0.
44