DCFM Installation, Migration, and Transition Guide - Supporting DCFM 10.3.x (53-1001360-01, October 2009)

Table Of Contents
DCFM Installation, Migration, and Transition Guide 97
53-1001360-01
Migrating from Professional edition 10.3.X to Professional Plus edition 10.3.X on Windows systems
2
8. Choose one of the following options to migrate data from a previous version.
To migrate data from a previous management application, you must do so now.
To migrate data from the previous version installed (automatically detected), select Yes,
from DCFM in the following location.
To browse to the previous version, select Yes, from EFCM, FM, or DCFM installed in this
machine or on network and click Browse to browse to the installation directory.
9. Click Next on the Copy Data and Settings screen.
An error message displays if any of the following occur:
NOTE
If legacy EFCM or FM software exist in the system, an Uninstall screen displays. Click Yes to
uninstall services of legacy EFCM and FM software.
10. Click Start on the Data Migration screen.
Data migration may take up to 30 minutes. When data migration is complete, the Professional
version is partially uninstalled.
11. Click Next on the Data Migration screen.
12. Choose one of the following options on the Server License screen.
13. Enter the serial number (on the DVD jewel case) and license key (on the Key Certificate) on the
Server License screen or browse to the license file (.xml) and click Next.
The License Key field is not case-sensitive.
14. Select Internal FTP Server or External FTP Server on the FTP Server screen and click Next.
The default selection reflects the previous Professional edition configuration.
If port 21 is busy, a message displays. Click OK to close the message and continue. Once the
Management application is configured make sure port 21 is free and restart the Server to start
the FTP service.
NOTE
If you select to use an FTP Server which is not configured on the same machine as DCFM, the
Firmware Repository feature will not be available.
Error Fix
Selected location is not valid or not supported. Browse to the correct location of the application.
Upgrade to a supported version.