Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)
24 Fabric OS Message Reference
53-1000600-02
AG-1004
2
Severity WARNING
AG-1004
Message <timestamp>, [AG-1004], <sequence-number>,, ERROR, <system-name>, Invalid
response to fabric login (FLOGI) request from the fabric for N_Port <port>.
Probable Cause Indicates that the fabric sent an invalid response to the FLOGI Extended Link Service (ELS) for the
specified N_Port.
Recommended
Action
Please check the configuration of the fabric switch.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
AG-1005
Message <timestamp>, [AG-1005], <sequence-number>,, WARNING, <system-name>, FDISC
response was dropped because F_Port <port> is offline.
Probable Cause Indicates that the F_Port connected to the host is offline, which caused the FDISC response to
drop.
Recommended
Action
Please check the configuration of the host connected to the specified F_Port.
Severity WARNING
AG-1006
Message <timestamp>, [AG-1006], <sequence-number>,, INFO, <system-name>, Access Gateway
mode has been <msg>.
Probable Cause Access Gateway mode has been enabled or disabled.
Recommended
Action
Please run ag --modeshow to verify the current status of the Access Gateway mode.
Severity INFO
AG-1007
Message <timestamp>, [AG-1007], <sequence-number>,, WARNING, <system-name>, FLOGI
response not received for the N_Port
<port> connected to the fabric.
Probable Cause Indicates that the N_Port connected to the fabric switch is not online. The specified N_Port has
been disabled.