Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)
Fabric OS Message Reference 281
53-1000600-02
HIL-1601
33
HIL-1601
Message <timestamp>, [HIL-1601], <sequence-number>,, ERROR, <system-name>, Using backup
temperature sensor. Service immediately.
Probable Cause Indicates that temperature readings from the primary sensor are out of range.
Recommended
Action
Run the fanShow command to verify that all fans are operating correctly. Replace any deteriorating
fan field-replaceable units (FRUs).
Run the tempShow command to verify temperature values. If any sensor is too high, monitor the
switch. Try rebooting or power cycling the switch.
Severity ERROR
HIL-1602
Message <timestamp>, [HIL-1602], <sequence-number>, FFDC, CRITICAL, <system-name>,
Multiple temperature sensors failed. Service immediately.
Probable Cause Indicates that temperature readings from multiple sensors are out of range.
Recommended
Action
Run the fanShow command to verify that all fans are operating correctly. Replace any deteriorating
fan field-replaceable units (FRUs).
Run the tempShow command to verify temperature values. If any sensor is too high, monitor the
switch. Try rebooting or power cycling the switch.
Severity CRITICAL
HIL-1603
Message <timestamp>, [HIL-1603], <sequence-number>, FFDC, CRITICAL, <system-name>,
<failure count> fans out of service. System is shutting down immediately.
Probable Cause Indicates that total fan failure count is greater than or equal to two.
Recommended
Action
In order to avoid causing damage to the switch, the system shuts down automatically. To help
prevent future problems, make sure that all the fans are working properly.
Severity CRITICAL
HIL-1650
Message <timestamp>, [HIL-1650], <sequence-number>, ERROR, <system-name>, <failure count>
unable to detect both WWN cards in chassis. Access to WWN halted.
Probable Cause One or both of the WWN cards is missing. Both WWN cards must be present for normal operation.
Recommended
Action
Make sure both WWN cards are inserted.