FCR-1073
22
FCR-1073
Message <timestamp>, [FCR-1073], <sequence-number>,, INFO, <system-name>, Switch with
domain ID <domain ID> in fabric <fabric ID> has lower limit of LSAN Zones
supported.
Probable Cause Indicates that a switch in the backbone/edge that supports different limit of logical storage area
network (LSAN) zones was detected.
Recommended
Action
Use the fcrResourceShow command on all Fibre Channel Routers in the Meta-SAN to find the
lowest supported LSAN zone limits. Please make sure that total number of LSAN zones in the
Meta-SAN are within the lowest supported limit of LSAN zone
Severity INFO
FCR-1074
Message <timestamp>, [FCR-1074], <sequence-number>,, ERROR, <system-name>, HA sync lost
as remote CP supports only <LSAN count> LSAN Zones.
Probable Cause Indicates that the remote control processor (CP) has older firmware, which only supports a lower
number of logical storage area network (LSAN) zones. This is causing the loss of the
high-availability (HA) sync.
Recommended
Action
Keep the number of LSAN Zones to the lower limit of the two CPs or upgrade the remote CP.
Severity ERROR
FCR-1075
Message <timestamp>, [FCR-1075], <sequence-number>,, ERROR, <system-name>, Zone Name
configuration is larger than <Zone Name Limit> characters in the edge fabric
connected to port <port numer>.
Probable Cause Indicates that the zone name configuration size created in the connected fabric exceeds the
maximum supported by the FC Router. This size is equal to the total number of characters used by
all the zone names in the edge fabric zoning database.
The limit includes both logical storage area network (LSAN) and Non-LSAN zone names defined in
zoning name database of the edge fabric.
Recommended
Action
Limit the zone configuration size in the edge fabric connected to this port by either reducing
number of zones or changing the zone names to smaller names.
Severity ERROR