Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

Fabric OS Message Reference 49
53-1000600-02
BL-1007
5
Probable Cause Indicates that the errors (mostly synchronization errors) on this blade are harmless. Probably, the
standby control processor (CP) blade connected to the active CP blade has experienced transitory
problems.
Recommended
Action
Use the haShow command to verify that the standby CP is healthy. If the standby CP was removed
or faulted by user intervention, no action is required.
Severity INFO
BL-1007
Message <timestamp>, [BL-1007], <sequence-number>,, WARNING, <system-name>, blade #<blade
number>: blade state is inconsistent with EM. bl_cflags 0x<blade control flags>,
slot_on <slot_on flag>, slot_off <slot_off flag>, faulty <faulty flag>, status
<blade status>.
Probable Cause Indicates that a failover occurred while a blade was initializing on the previously active control
processor (CP).
Recommended
Action
No action is required. The blade is reinitialized. Because reinitializing a blade is a disruptive
operation and can stop I/O traffic, you might have to stop and restart the traffic during this process.
Severity WARNING
BL-1008
Message <timestamp>, [BL-1008], <sequence-number>, FFDC, CRITICAL, <system-name>, Slot
<slot number> control-plane failure. Expected value: 0x<value 1>, Actual: 0x<value
2>.
Probable Cause Indicates that the blade has experienced a hardware failure or was removed without following the
recommended removal procedure.
Recommended
Action
Make sure that the blade is seated correctly.
If the blade is seated correctly, reboot or power cycle the blade.
Run the systemVerification command to verify that the blade does not have hardware problems.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric
OS Command Reference for more information on these commands.
If the message persists, replace the blade.
Severity CRITICAL
BL-1009
Message <timestamp>, [BL-1009], <sequence-number>, FFDC, CRITICAL, <system-name>, Blade
in slot
<slot number> timed out initializing the chips.
Probable Cause Indicates that the blade has failed to initialize the application-specific integrated circuit (ASIC)
chips.