HP B-series Fabric OS 7.1.0c Release Notes (5697-2892, October 2013 - includes all 7.1.0x versions)

Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.Zone DB distribution fails to reach all domains in the fabric.
Fixed in Fabric OS 7.1.0.The SSHutil command fails for user names containing
upper case letters.
Workaround prior to upgrade:Ports on the 8 Gb/s switches running Fabric OS 7.0.0 or
later may negotiate to a 4 Gb/s speed even though the
link is capable of running at 8 Gb/s or higher.
Lock to a fixed speed.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Unable to set the Timezone correctly on the systems of
countries that do not change time between standard and
daylight savings time.
Fixed in Fabric OS 7.1.0.Switches experience excessive CF usage due to generation
of the /var/log/ag_desc.txt.
Workaround prior to upgrade:There is an unsupported port speed configuration after
replacing an HP SN8000B 16Gb 32-port Fibre Channel
Manually correct the configured port speed and re-enable
the port.
Blade/HP SN8000B 16Gb 48-port Fibre Channel Blade
blade with an HP SAN Director 16-port 8Gb FC Blade/
Fixed in Fabric OS 7.1.0.
HP SAN Director 32-port 8Gb FC Blade/ HP SAN Director
48-port 8Gb FC Blade.
Fixed in Fabric OS 7.1.0.Hosts are unable to discover targets across the backbone
fabric with the HP 1606 SAN Extension Switch/ HP DC
SAN Director Multiprotocol Extension Blade in the
configuration.
Fixed in Fabric OS 7.1.0.Emulated FICON Tape Read Channel Program can grow
too large, resulting in FICON Protocol timeouts and aborts.
Fixed in Fabric OS 7.1.0.Enhanced SerDes tuning needed to address CRC with good
EOF errors.
Fixed in Fabric OS 7.1.0.A host is unable to Link up on an 8 Gb/s FC port when
the port is configured at a fixed speed of 4 Gb/s or 8
Gb/s.
Fixed in Fabric OS 7.1.0.A panic occurs in FCP Tape Emulation when retransmitting
previously sent partial frames because the gather buffer
count is too high.
Workaround prior to upgrade:FastWrite fails in a multi-hop VE-XISL configuration with
the HP 1606 SAN Extension Switch/ HP DC SAN Director
Multiprotocol Extension Blade in the configuration.
Disable FCIP Fastwrite and OSTP on the VE XISL.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Enabling track changes in native mode keeps the feature
active when AG mode is enabled but the CLI no longer
works.
Fixed in Fabric OS 7.1.0.The network scanning application causes high CPU
utilization by the CNM daemon.
Fixed in Fabric OS 7.1.0.In a FICON environment, XRC emulation sets the incorrect
sequence count and sequence ID on re-driven RRS Chain
after getting an immediate command retry status.
Workaround prior to upgrade:A switch Ethernet port sends frames with invalid MAC
addresses on the Brocade HP 8/8 e-port SAN Switch, HP
Use 100 Half duplex instead of Full Duplex mode.
8/40 SAN Switch, HP SN6000B 16Gb FC switch, and
the HP 1606 SAN Extension Switch.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.GA_NXT is not transferring the symbolic names (port or
node) from the non-local device table.
50