Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.The perfaddusermonitor/fmconfig are not correctly
detecting SOFf frame ingress/egress when filter monitor
is enabled.
Fixed in Fabric OS 7.1.0.IDLE not being sent after NOS - results in other issues and
eventually causes the port to become a G_Port.
Fixed in Fabric OS 7.1.0.Frame drops are observed after changing the FCR
backbone domain ID.
Fixed in Fabric OS 7.1.0.Access Gateway does not clean up frame exchange
properly if FLOGI/FDISC comes in from different ports
together with same exchange ID (OX-ID).
Fixed in Fabric OS 7.1.0.Firmware upgrades from Fabric OS 6.4 to 7.0 is blocked,
and the user does not get sufficient information from the
error message.
Workaround prior to upgrade:A kernel panic occurs following the insertion/removal of
SFPs on an HP 2408 FCoE Converged Network Switch.
Avoid reseating SFPs in a quick succession.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Configdownload fails with specific timezones.
Fixed in Fabric OS 7.1.0.When Loop port (JBOD) and EX port are in the same chip
and LSAN is in place, Loop port drops the PLOGI accept
to the host and device discovery will fail.
Fixed in Fabric OS 7.1.0.During switch/blade initialization, the HP 1606 SAN
Extension Switch and the HP DC SAN Director
Multiprotocol Extension Blade forward BDPU broadcast
frames and users will see their Ethernet switch ports fenced
offline.
Fixed in Fabric OS 7.1.0.FICON XRC is suspended and LOGREC entries with
Command Rejects are displayed with the reason code
0x0F61 against a 0xFF command.
Fixed in Fabric OS 7.1.0.Users may notice excessive port errors (enc out) on HP 8/8
SAN Switch/ HP 8/24 SAN Switch ISL ports in a
configuration consisting of a mix of 4 Gb/s user ports
interconnected via 8 Gb/s ISLs.
Fixed in Fabric OS 7.1.0.A tape device connected to an HP Encryption SAN Switch
is dropping frames.
Fixed in Fabric OS 7.1.0.The perfttmon --show parser options have an
unexpected output.
Workaround prior to upgrade:There is an FCIP Tunnel bounce caused by chip reset on
an HP DC SAN Director Multiprotocol Extension Blade.
Disabling IPsec may help avoid this issue.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:Cold recovery observed when devices are not LSAN zoned
but are exchanging ELS frames.
Use LSAN zone or make sure devices do not statically
remember old proxy IDs.