TRCE-1010
106
TRCE-1010
Message <timestamp>, [TRCE-1010], <sequence-number>,, ERROR, <system-name>, Traced fails
to start
Probable Cause Indicates that the trace daemon (traced), used for transferring trace files, failed to start. The trace
capability within the switch is unaffected. The traced facility is normally restarted automatically by
the system after a brief delay.
Recommended
Action
If the message persists, restart the CP (dual-CP system) or restart the switch.
Run the supportFtp command to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.
Severity ERROR
TRCE-1011
Message <timestamp>, [TRCE-1011], <sequence-number>,, INFO, <system-name>, Trace dump
manually transferred to target ' <optional string to indicate which slot the dump
is ftped out.> ': <result>.
Probable Cause Indicates that a manual transfer of trace dump files has occurred.
Recommended
Action
No action is required.
Severity INFO
TRCE-1012
Message <timestamp>, [TRCE-1012], <sequence-number>,, WARNING, <system-name>, The system
was unable to retrieve trace information from slot <Slot number of the blade the
attempt was made on>.
Probable Cause Indicates that communication between the main system and the indicated slot is unavailable.
Recommended
Action
Make sure the blade is enabled and retry the command. If the blade is already enabled, run the
supportSave command and contact your switch service provider.
Severity WARNING