Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 705
53-1002448-01
SULB-1039
101
SULB-1039
Message <timestamp>, [SULB-1039], <sequence-number>, INFO, <system-name>, CP has
completed relocating the internal firmware image.
Probable Cause Indicates that the firmwareDownload command process has been completed normally on the CP.
Recommended
Action
Run the firmwareShow command to verify the firmware versions.
Severity INFO
SULB-1040
Message <timestamp>, [SULB-1040], <sequence-number>, WARNING, <system-name>, An error has
occurred during relocation of the internal image on the CP.
Probable Cause Indicates an error has occurred during the relocation of the internal image. The error may be
caused by inconsistent internal firmware image. It may also be caused by the internal Ethernet
failure.
Recommended
Action
Run the firmwareShow command to verify the firmware versions. Run the firmwareDownload
command again if the firmware is not updated.
This will cause the internal image to be relocated again. If the problem persists, contact your switch
service provider.
Severity WARNING
SULB-1041
Message <timestamp>, [SULB-1041], <sequence-number>, INFO, <system-name>, Firmware has
been activated successfully on standby CP.
Probable Cause Indicates the firmwareActivate command has completed successfully on standby CP.
Recommended
Action
No action is required. The firmwareActivate command has completed on standby CP as expected.
Run the firmwareShow command to verify the firmware versions.
Severity INFO
SULB-1042
Message <timestamp>, [SULB-1042], <sequence-number>, INFO, <system-name>,
Firmwareactivate command has completed successfully.
Probable Cause Indicates the firmwareActivate command has completed successfully and switch firmware has
been updated.