Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

596 Fabric OS Message Reference
53-1002448-01
SEC-1080
94
Recommended
Action
Run the command again using a valid policy name.
Severity ERROR
SEC-1080
Message <timestamp>, [SEC-1080], <sequence-number>,, ERROR, <system-name>, Operation
denied. Please, use secModeEnable command.
Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR
SEC-1081
Message <timestamp>, [SEC-1081], <sequence-number>,, ERROR, <system-name>, Entered a name
for a DCC policy ID that was not unique.
Probable Cause Indicates the device connection control (DCC) policy name given in the secPolicyCreate command
was the same as another DCC policy.
Recommended
Action
Make sure that the DCC policy name has a unique alphanumeric string, and run the
secPolicyCreate command again.
Severity ERROR
SEC-1082
Message <timestamp>, [SEC-1082], <sequence-number>,, ERROR, <system-name>, Failed to
create <policy name> policy.
Probable Cause Indicates the security policy was not created due to faulty input or low resources.
Recommended
Action
Use proper syntax when creating policies. If the security database is too large, you must delete
other members within the database before adding new members to a policy.
Severity ERROR