Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)
Fabric OS Message Reference 591
53-1002448-01
SEC-1055
94
SEC-1055
Message <timestamp>, [SEC-1055], <sequence-number>,, ERROR, <system-name>, Invalid FCS
list <WWN list>.
Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR
SEC-1056
Message <timestamp>, [SEC-1056], <sequence-number>,, ERROR, <system-name>, Invalid
position <New position>. Only <Number of members in FCS list> members in list.
Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configurations server (FCS) is distributing the security database to
the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR
SEC-1057
Message <timestamp>, [SEC-1057], <sequence-number>,, ERROR, <system-name>, No change.
Both positions are the same.
Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR