Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)
580 Fabric OS Message Reference
53-1002448-01
SEC-1003
94
SEC-1003
Message <timestamp>, [SEC-1003], <sequence-number>,, WARNING, <system-name>, Fail to
download security data to domain <Domain number> after <Number of retires>
retries.
Probable Cause Indicates the specified domain has failed to download security data after the specified number of
attempts, and that the failed switch encountered an error accepting the database download. The
primary switch will segment the failed switch after 30 tries.
Recommended
Action
Reset the version stamp on the switch to 0 using the secVersionReset command and then rejoin
the switch to the fabric.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity WARNING
SEC-1005
Message <timestamp>, [SEC-1005], <sequence-number>,, INFO, <system-name>, Primary FCS
receives data request from domain <Domain number>.
Probable Cause Indicates the primary fabric configuration server (FCS) received a data request from the specified
domain. For example, if the switch fails to update the database or is attacked (data injection), a
message is generated to the primary FCS to try to correct and resynchronize with the rest of the
switches in the fabric.
Recommended
Action
Use the secFabricShow command to check whether any of the switches in the fabric encountered
an error. If one or more switches are not in the Ready state, and you have reason to believe that the
error is the result of a possible security breach, take appropriate action as defined by your
enterprise security policy.
Severity INFO
SEC-1006
Message <timestamp>, [SEC-1006], <sequence-number>,, WARNING, <system-name>, Security
statistics error: Failed to reset due to invalid <data>.
Probable Cause Indicates that invalid data has been received for any statistic-related command for security
(secStatsShow or secStatsReset). The counter is updated automatically when a security violation
occurs. This message might also occur if the updating counter fails.
Recommended
Action
If the message is the result of a user command, retry the statistic command.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING