Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

436 Fabric OS Message Reference
53-1002448-01
HIL-1308
48
HIL-1308
Message <timestamp>, [HIL-1308], <sequence-number>,, ERROR, <system-name>, All fans
failed. Replace failed fan FRUs immediately.
Probable Cause Indicates that all fans have failed. This message is often preceded by a low fan speed message.
Recommended
Action
Replace the faulty fan field-replaceable units (FRUs) immediately.
Severity ERROR
HIL-1309
Message <timestamp>, [HIL-1309], <sequence-number>,, ERROR, <system-name>, <count> fan
FRUs failed. Replace failed fan FRUs immediately.
Probable Cause Indicates that multiple fans have failed. This message is often preceded by a low fan speed
message.
Recommended
Action
Replace the faulty fan field-replaceable unit (FRU)s immediately.
Severity ERROR
HIL-1310
Message <timestamp>, [HIL-1310], <sequence-number>,, WARNING, <system-name>, <count> fans
faulty.
Probable Cause Indicates that multiple fans have failed. This message is often preceded by a low fan speed
message.
Recommended
Action
Since the fans are not field replaceable, replace the switch if the temperature is high.
Severity WARNING
HIL-1311
Message <timestamp>, [HIL-1311], <sequence-number>,, INFO, <system-name>, No fans are
faulty.
Probable Cause Indicates recovery from earlier condition of one or more fans having failed.
Recommended
Action
This can only occur on switches with non-removable fans. It follows a previous indication of
faultiness.