Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 407
53-1002448-01
FW-1510
45
Recommended
Action
Reconfigure a valid e-mail address.
Severity WARNING
FW-1510
Message <timestamp>, [FW-1510], <sequence-number>,, WARNING, <system-name>, <Area string>
threshold exceeded(High=<Threshold high>). Current value is <Current value>: Port
<Port number> disabled.
Probable Cause Indicates that the specified port is now disabled because the link on this port had multiple link
failures that exceed Fabric Watch threshold on the port. Both physical and hardware problems can
cause link failures. Link failures frequently occur due to a loss of synchronization. Link failures also
occur due to hardware failures, a defective small form-factor pluggable (SFP) or faulty cable.
Protocol errors indicates CRC sum disparity. Occasionally, these errors occur due to software
glitches. Persistent errors occur due to hardware problems.
Recommended
Action
Check for concurrent loss of synchronization errors. Check the SFP and the cable. Then, enable the
port using the portEnable command.
Severity WARNING
FW-1511
Message <timestamp>, [FW-1511], <sequence-number>,, INFO, <system-name>, <Port Name>,
<Label>, has crossed lower threshold boundary to in between(High=<High value>,
Low=<Low value>). Current value is <Value> <Unit>.
Probable Cause Indicates that the number of link failures that the port experiences has changed and crossed lower
threshold boundary to a value within the acceptable range. Link loss errors occur when a link
experiences a loss of signal and fails. Both physical and hardware problems can cause link loss
errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss
of synchronization errors and, if applicable, troubleshoot them.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity INFO