Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 81
53-1002448-01
BL-1031
7
BL-1031
Message <timestamp>, [BL-1031], <sequence-number>,, CRITICAL, <system-name>, Link timeout
in internal port (slot <Slot number>, port <Port number>) resulted in blade fault.
Use slotpoweroff/slotpoweron to recover the blade.
Probable Cause Indicates that link timeout occurred in one of the backend internal ports.
Recommended
Action
Power cycle the blade or run the slotPowerOff and slotPowerOn commands.
Severity CRITICAL
BL-1032
Message <timestamp>, [BL-1032], <sequence-number>,, CRITICAL, <system-name>, (slot <slot
number>,bitmap 0x<object control flags(bitmap)>) ports never came up ONLINE
(reason <reason for port disable>, state <status of the blade>). Disabling slot.
Probable Cause Indicates that back-end (non-user) ports have not come ONLINE within time limit.
Recommended
Action
Restart or power cycle the blade. Run the diagPost command to ensure that Power-On Self-Test
(POST) is enabled. If the message persists, replace the blade.
Severity CRITICAL
BL-1033
Message <timestamp>, [BL-1033], <sequence-number>,, CRITICAL, <system-name>, (slot <slot
number>,bitmap 0x<object control flags(bitmap)>) No disable acknowledgment from
ports (state <status of the blade>). Disabling slot.
Probable Cause Indicates that the system has timed out while waiting for disable messages from the user ports
after disabling the ports.
Recommended
Action
Restart or power cycle the blade. Run the diagPost command to ensure that Power-On Self-Test
(POST) is enabled. If the message persists, replace the blade.
Severity CRITICAL
BL-1034
Message <timestamp>, [BL-1034], <sequence-number>,, INFO, <system-name>, Slot <slot
number>
FC Initialization completed.
Probable Cause Indicates that the slot has completed initializing Fibre Channel (FC) ports.