Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

78 Fabric OS Message Reference
53-1002448-01
BL-1021
7
BL-1021
Message <timestamp>, [BL-1021], <sequence-number>,, INFO, <system-name>, Retry <Retry
Number>, internal port retry initialization, <List of internal ports retrying
initialization>.
Probable Cause Indicates that the switch had internal ports not online and that the system is retrying to bring the
ports that failed back online.
Recommended
Action
No action is required.
Severity INFO
BL-1022
Message <timestamp>, [BL-1022], <sequence-number>,, CRITICAL, <system-name>, Init Failed:
Switch DISABLED because internal ports were not ONLINE,
<list of internal port
number not ONLINE>.
Probable Cause Indicates that the switch initiation failed because one or more of the internal ports was not online.
The switch is faulted.
Recommended
Action
Restart or power cycle the switch.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric
OS Command Reference for more information on these commands.
Additional fault messages precede and follow this error, providing more information. See other
error messages for recommended action.
If the message persists, replace the switch.
Severity CRITICAL
BL-1023
Message <timestamp>, [BL-1023], <sequence-number>,, CRITICAL, <system-name>, Blade in
slot
<slot number> was reset before blade init completed. As a result the blade
is faulted.
Probable Cause Indicates that the blade was reset before the initialization completed.
Recommended
Action
Restart or power cycle the blade.
If the message persists, replace the blade.
Severity CRITICAL