HP 3PAR F-Class, T-Class, StoreServ 10000 Storage Troubleshooting Guide (QL226-96953, May 2013)

Table 33 Drive Cage DC4 FC-AL Module LEDs (continued)
IndicatesAppearanceLED
FC-AL module error or other cage error.
If both FC-AL modules have a steady
light, the temperature of a disk drive in
the drive-cage has exceeded its
high-level threshold, or a power supply
has failed.
The drive cage has some type of error,
such as a failed or missing power
Flashing amber light (1 blink per
second)
supply, but is communicating with a
node.
A cage firmware upgrade initiated by
the upgradecage CLI command is
Rapid toggle between amber and
green light
in progress. A firmware upgrade
normally takes less than two minutes to
complete.
The FC-AL module is prepared for hot
plug replacement.
Steady amber lightHot plug
The FC-AL module is not prepared for
hot plug.
No light
The transfer rate is operating at 4GB/s.Steady green light4GB/s
The transfer rate is not operating at
4GB/s.
No light
82 Understanding HP 3PAR StoreServ 10000 Storage LED Status