HP 3PAR Command Line Interface Reference (OS 3.1.2 MU2) (QL226-97016, June 2013)

Performs the same function as RawSpaceAlertFC, but should be used for Serial Attached SCSI
type drives
RemoteSyslog <value>
Enables or disables sending events as syslog messages to a remote system. A value of 0 disables
the message, and a value of 1 enables the message. syslog messages are sent with a facility
user and with event severities mapped to syslog levels such as:
Table 7 Event severity
syslog LevelEvent Severity
alertfatal
alertcritical
critmajor
errminor
warningdegraded
infoinfo
RemoteSyslogHost <value>
Sets the IP address of the system to which events will be sent as syslog messages. The value must
be a valid IP address.
SparingAlgorithm <value>
Sets the sparing algorithm used by the admithw command. Valid values are Default, Minimal,
Maximal, and Custom.
MgmtOldPorts <value>
Enables or disables listening on the old management ports 2540 and 2550 (for SSL). The server
now listens on ports 5782 and 5783 (for SSL). By default, the server also listens on the old ports
unless they are disabled using this parameter. The value must be either enable or disable.
Default ports 2540 and 2550 were deprecated in the 2.2.4 release and support for them will be
removed in a future release.
NOTE: The server must be restarted for changes made with the MgmtOldPorts parameter to
take effect.
RemoteCopyOldPort <value>
Enables or disables listening on the old TCP port 3491. The value must be either enable or
disable. By default, Remote Copy links listen on both IANA registered port 5785 AND port
3491.
WARNING! Changing this parameter will reset all Remote Copy links. This may cause Remote
Copy targets to lose their connections temporarily.
VVRetentionTimeMax <value>[h|H|d|D]
Specifies the maximum value that can be set for the retention time of a volume. <time> is a positive
integer value and in the range of 0 - 43,800 hours (1,825 days). Time can be optionally specified
in days or hours providing either d or D for day and h or H for hours following the entered time
value. The default value for <time> is 14 days.
To disable setting the volume retention time in the system, enter 0 for <time>.
UpgradeNote <value>
Sets a note that will be displayed when checkupgrade is run. To include spaces, enclose the
value inside double quotes. To erase an existing note, specify "". Maximum length is 127 characters.
334 Set Commands