statvv
DESCRIPTION
The statvv command displays statistics for Virtual Volumes (VVs) in a timed loop.
SYNTAX
statvv [options <arg>] [<VV_name_or_pattern>...]
AUTHORITY
Any role in the system.
OPTIONS
-domain <domain_name|pattern>...
Shows only the VVs that are in domains with names that match the specified domain names or
patterns.
rw
Specifies that the display includes separate read and write data. If not specified, the total is
displayed.
d <seconds>
Specifies the interval, in seconds, that statistics are sampled using an integer from 1 through
2147483. If no interval is specified, the option defaults to an interval of two seconds.
iter <number>
Specifies that the histogram is to stop after the indicated number of iterations using an integer from
1 through 2147483647.
sortcol <col> [,<dir>][:<col>[,<dir>]...]
Sorts command output based on the column number (<col>). Columns are numbered from left to
right, beginning with 0. At least one column must be specified. In addition, the direction of sorting
(<dir>) can be specified as follows:
inc
Sort in increasing order (default).
dec
Sort in decreasing order.
Multiple columns can be specified separated by a colon (:) Rows with the same information in
them as earlier columns will be sorted by the values in the later columns.
filt <fspec>
statvv 629