HP 3PAR F-Class, T-Class, StoreServ 10000 Storage Troubleshooting Guide (QL226-96953, May 2013)

Table 22 Drive Chassis OPs Panel LED Displays
IndicatesAppearanceLED
Used in conjunction with Power Supply/Cooling/Temperature
Fault LED, 2GB Link Speed LED, Invalid Address LED, and System
Fault LED as described below.
Steady green lightPower On
Steady amber lightPower
Supply/Cooling/Temperature
Fault LED
Test state (5 seconds), if:
Power On LED is steady green.
System Fault LED is steady amber.
Invalid Address LED is steady amber.
2GB Link Speed LED is steady green.
Power supply or fan fault, if:
Power On LED is steady green.
System Fault LED is off.
Over or under temperature, if:
Power On LED is steady green.
System Fault LED is flashing amber.
Flashing amber light
One power supply is removed if:
Power On LED is steady green.
System Fault LED is flashing amber.
OPs to ESI communications failed, if:
Power On LED is steady green.
System Fault LED is steady amber.
Steady green light2GBLink Speed LED
Test state (5 seconds), if:
Power On LED is steady green.
Power Supply/Cooling/Temperature Fault LED is steady
amber.
System Fault LED is steady amber.
Invalid Address LED is steady amber.
2GB drive loop is selected, if Power On LED is steady green.
One or more drives are bypassed on at least one loop.Flashing green light
The 5V aux is present, overall power fail, if Power On LED is
green and all other LEDs are off.
No green light