untested battery will have an Unknown status in the showbattery -s output. Use commands
such as showbattery, showbattery -s, showbattery -d, and showbattery -log.
showbattery -s
Node PS Bat -State-- -Detailed_State-
0 0 0 OK normal
0 1 0 Degraded Unknown
Examine the date of the last successful test of that battery. Assuming the comment date was
2009-10-14, the last battery test on Node 0, PS 1, Bat 0 was 2009-09-10, which is more
than 30 days in the past.
showbattery -log
Node PS Bat Test Result Dur(mins) ---------Time----------
0 0 0 0 Passed 1 2009-10-14 14:34:50 PDT
0 0 0 1 Passed 1 2009-10-28 14:36:57 PDT
0 1 0 0 Passed 1 2009-08-27 06:17:44 PDT
0 1 0 1 Passed 1 2009-09-10 06:19:34 PDT
showbattery
Node PS Bat Serial -State-- ChrgLvl(%) -ExpDate-- Expired Testing
0 0 0 83205243 OK 100 04/07/2011 No No
0 1 0 83202356 Degraded 100 04/07/2011 No No
PD
Displays Physical Disks (PDs) with states or conditions that are not optimal.
Checks for failed and degraded PDs
Checks for an imbalance of PD ports, for example, if Port-A is used on more disks than Port-B
Checks for an "Unknown" Sparing Algorithm. For example, when it hasn't been set
Checks for disks experiencing a high number of IOPS
Reports if a servicemag operation is outstanding (servicemag status)
Reports if there are PDs that do not have entries in the firwmare DB file
Format of Possible PD Exception Messages
PD disk:<pdid> "Degraded States: <showpd -s -degraded">
PD disk:<pdid> "Failed States: <showpd -s -failed">
PD -- "There is an imbalance of active PD ports"
PD -- "Sparing algorithm is not set"
PD disk:<pdid> "Disk is experiencing a high level of I/O per second: <iops>"
PD -- There is at least one active servicemag operation in progress
The following checks are performed when the -svc option is used, or on 7400/7200 hardware:
PD File: <filename> "Folder not found on all Nodes in <folder>"
PD File: <filename> "Folder not found on some Nodes in <folder>"
PD File: <filename> "File not found on all Nodes in <folder>"
PD File: <filename> "File not found on some Nodes in <folder>"
PD Disk:<pdID> "<pdmodel> PD for cage type <cagetype> in cage position <pos> is missing
from firmware database"
114 Troubleshooting