3PAR InForm® OS 2.3.1 Messages and Operator's Guide (320-200181 Rev B, February 2010)

12.10
Messages and Operator’s Guide InForm OS Version 2.3.1
STATE 7
Read Label Failed
SUGGESTED ACTION
The PD specified in the alert has been marked failed because the disk label could not be read
from the disk. Use the CLI command showpd <pd_id> to confirm the disk is still in this state.
If the error is persistent, contact your local service provider for possible disk replacement.
STATE 8
Invalid Label
SUGGESTED ACTION
The PD specified in the alert has been marked failed because the disk label read from the disk
cannot be validated. Use the CLI command showpd <pd_id> to confirm the disk is still in this
state.
If the error is persistent, contact your local service provider for possible disk replacement.
STATE 9
Invalid Capacity
SUGGESTED ACTION
The PD specified in the alert has been marked failed because the capacity of
the disk read by a SCSI inquiry is different from the matching entry in a list of supported values.
Use the CLI command
showpd <pd_id> to confirm the disk is still in this state.
Contact your local service provider for possible disk replacement.
STATE 10
Invalid Type
SUGGESTED ACTION
The PD specified in the alert has been marked failed because the vendor of the disk is not
included in the list of supported vendors. Use the CLI command
showpd <pd_id> to confirm
the disk is still in this state.
Contact your local service provider for possible disk replacement.
STATE 11
Invalid Firmware