3PAR InForm® OS 2.3.1 Messages and Operator's Guide (320-200181 Rev B, February 2010)

11.9
Troubleshooting InServ Storage Server Components
InForm OS Version 2.3.1 Messages and Operator’s Guide
VendorId,ProductId 3PARdata,DC2
Unique_ID 10320300000AD000
Power Supply Info State Fan State AC Model
ps0 Failed OK Failed POI <AC input is missing
ps1 OK OK OK POI
ps2 Off OK OK POI <PS switch is turned off
ps3 OK OK OK POI
11.4.2.6 Cage Example 3
Component -Identifier- --------------Description----------------
Cage cage:1 Cage has a hotplug enabled interface card
11.4.2.7 Cage Suggested Action 3
When a servicecage operation is started, it puts the targeted cage into servicing mode and
illuminates the Hot Plug LED on the FCAL-Module (DC1, DC2, DC4), and causes I/O to be routed
through the other path. When the service action is finished, the
servicecage endfc
command should be issued to return the cage to normal status. This
checkhealth exception
will be reported if the FCAL-Module's Hot Plug LED is illuminated or if the cage is in servicing
mode. If a maintenance activity is currently occurring on the drive cage, this condition may be
ignored.
cli% showcage -d cage1
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side
1 cage1 0:0:2 0 1:0:2 0 24 28-40 2.37 2.37 DC2 n/a
-----------Cage detail info for cage1 ---------
Interface Board Info FCAL0 FCAL1
Link A RXLEDs Green Off
Link A TXLEDs Green Off
Link B RXLEDs Off Green
Link B TXLEDs Off Green
LED(Loop_Split) Off Off
LEDS(system,hotplug) Green,Off Green,Amber
-----------Midplane Info-----------
Firmware_status Current
NOTE: The primary path can be seen by an asterisk (*) in showpd's Ports
columns.