3PAR InForm® OS 2.3.1 CLI Reference (320-200166 Rev B, March 2010)
22.9
InForm OS Version 2.3.1 Command Line Interface Reference
EXAMPLES
The following example displays battery status information:
The columns in the previous example are identified as follows:
■ Node. The controller node number.
■ PS. The power supply number.
■ Bat. The battery ID.
■ Serial. The battery serial number.
■ State. The current status of the battery. Battery states can be as follows:
◆ --. Cannot determine the battery state.
◆ NotPresent. Battery is missing.
◆ OK. Battery is operating normally.
◆ Failed. Battery is operating abnormally.
◆ MaxLifeLow. Maximum battery life is low (less than 12 minutes).
■ ChgLvl. Percentage of battery charge status for the node.
■ ExpDate. The expiration date of the battery.
■ Expired. Indicates whether expired batteries are connected to the power supply.
■ Testing. Indicates whether a battery test is in progress. When a battery test is in progress,
the batteries cannot be counted so the number of batteries shown is a cached value.
cli% showbattery
Node PS Bat Serial --State--- ChrgLvl(%) -ExpDate-- Expired Testing
0 0 0 FFFFFFFF OK 100 05/15/2007 No No
0 1 0 FFFFFFFF OK 100 05/15/2007 No No
1 0 0 -- NotPresent -- -- No No
1 1 0 -- NotPresent -- -- No No