HP 3PAR OS 3.1.2 Release Notes Abstract This document describes the features and issues included in HP 3PAR OS 3.1.2 and is intended for use by HP customers, partners, and HP field representatives. This document is applicable to HP 3PAR OS 3.1.2.278 (GA), HP 3PAR OS 3.1.2.322 (MU1), HP 3PAR OS 3.1.2.422 (MU2), HP 3PAR OS 3.1.2.422 (EMU2), HP 3PAR OS 3.1.2.484 (MU3), and HP 3PAR OS 3.1.2.592 (MU5).
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
Contents 1 HP 3PAR OS 3.1.2 GA Release Notes...........................................................5 Online Upgrade Considerations.................................................................................................5 Supported Platforms..................................................................................................................5 End of Support Features............................................................................................................5 Components.
Known Issues with the OS........................................................................................................41 Cannot downgrade from 3.1.2.422 (MU2) to an earlier release on specific storage systems (Bug 86680)............................................................................................................................41 Kernel Core when performing online upgrade from 3.1.2.322 MU1 to 3.1.2.412 (Bug 89407).....................................................................
1 HP 3PAR OS 3.1.2 GA Release Notes Online Upgrade Considerations This feature allows the upgrade of the OS concurrently with I/O activity on the attached hosts, provided certain conditions are met. For further information and pre-planning of online upgrades, refer to the latest version of the HP 3PAR OS Upgrade Pre-Planning Guide. To obtain a copy of this documentation, go to http://www.hp.com/3par/support_manuals, select your product, and then click Manuals. WARNING! Beginning with HP 3PAR OS 3.1.
What’s New in the OS HP 3PAR OS 3.1.2 enables customers to increase multi-tenant consolidation on shared infrastructure and increase agility and efficiency with several new features and enhancements. HP 3PAR OS 3.1.2 supports the new HP 3PAR StoreServ 7000 Storage. HP 3PAR OS 3.1.
Autonomic Management for Agility and Ease of Use • HP 3PAR Adaptive Optimization software has been enhanced to support all manageability and configuration using HP 3PAR management console and CLI. The data for AO is now maintained on the StoreServ Storage in an internal database. • Autonomic Rebalance capability is now available as part of the HP 3PAR OS.
Other Enhancements • Provides the ability to force the shutdown of the HP 3PAR StoreServ Storage node for maintenance if there are active tasks running without having to manually stop all the tasks before shutting down the node for maintenance. HP 3PAR Remote Copy software now leverages the HP 3PAR Thin Built-In ASIC to detect and eliminate the remote replication of zero pages during initial synchronization and ongoing synchronous replication.
Issue ID Item Description 54956 2.3.1 MU1: sysmgr panicked, system When resynchronizing a volume over 2TB in size to a rcopy secondary pending pfail recovery system, a 32bit counter used to represent the number of contiguous blocks which has ""delta"" data since the last resync may overflow. HP 3PAR OS has since been enhanced to use 64bit counters.
Issue ID Item Description 62000 setvv -snp_cpg behavior with shared logical disks corrected Using setvv -snp_cpg on virtual volumes relying on shared logical disks was causing a panic of the system manager. The behavior of setvv has been corrected: now all the virtual volumes sharing logical disks must be specified as arguments, otherwise the command will fail.
Issue ID Item Description coherent and let the battery charge level to set to normal. On releases before 2.3.1.MU5, there's no workaround that would fix the problem without interrupting system. On such system, the only way to get the system to work normally is to restart sysmgr.
Issue ID Item Description switches, show fcns database detail will display this information. HP's SAN Visibility software will key off this information. 12 65930 Improve peer motion performance for full VVs Earlier full VVs used to be in writethru during import, and this impacted the VV performance as more regions are moved to local LDs over time. Now full VV and TPVV volumes are imported in the same way and the local LDs are no longer in writethru.
Issue ID Item Description to facilitate expedited synchronization post migration. This functionality was integrated into the createsv command, using the -rcopy switch. 67556 Help for createsv CLI command does createsv now alows read-write snapshot creation from read-write not reflect changes to functionality base/read-write snapshots 67913 Firmware issue could cause port resets due to mailbox command timeouts Upgraded 1G iSCSI firmware to version 3.0.1.
Issue ID Item 70797 VV state returns to "normal" if a tune In previous HP 3PAR releases, when a VV tune is cancelled the is cancelled displayed VV state remained at ""tuning"" indicating that the tune must be completed (re-run) or rolled back in order to return the VV state to normal. This behavior changes in 3.1.2 as the VV state returns to ""normal immediately on task cancellation.
Issue ID Item Description device entry, thus the follow-up operations (e.g. LOGO) caused a host being wrongly disconnected. 78498 Sysmgr Unresponsive Fixed a defect in the sysmgr subsystem that could cause the sysmgr to be unresponsive and for host io to be blocked. Operations involving a region move (such as tunes) or a node integration could get the sysmgr into this state. Fixed the race condition between the sysmgr and kernel that caused this behavior.
Issue ID Item Description 68387 CLI command controlport rst Using CLI command controlport rst -l on a 10G iSCSI port -l can lead to fatal PCI errors under heavy host I/O can lead to fatal PCI errors and a subsequent node reboot. 68839 User guide edits Need to remove references to the MENU Driven Application from the UG if it is deprecated. 68840 Menu Driven Application deprecated Need to update RMO 4.
Issue ID Item Description The only impact this has is the suspension of periodic resyncs for the duration of the online upgrade. 81222 eventlog: Critical Cluster thermal shutdown seen during soft reset of DCN1 cages After a soft reset of the DCN1 cage's controllers, we noticed the following events being generated. 2012-10-26 09:27:41 PDT 0 Critical Cluster thermal shutdown hw_node:0 Node 0 We have not noticed any issues caused by the generation of this event.
Improving the transition time in a future release is planned. • Solaris 11 with Brocade Fabric Occasionally, Solaris hosts that are attached through a Brocade fabric lose paths after a failover or failback. In this case the host seems to have a problem with multiple FC_IDs referenced in the RSCN payload from the switch. This is an intermittent issue seen about 10% of the time. Ultimately the fix for this needs to be done on the host and is currently being investigated. • RHEL 6.
2 HP 3PAR OS CLI Release Notes Installation Notes for the OS CLI Virus Checking Virus checking is known to slow down and potentially cause issues with installation of the OS CLI. Before attempting an install or uninstall of the OS CLI, shut down all running applications and disable virus-checking software. What’s New in the OS CLI The following features are added/removed for OS 3.1.2 CLI: • OS CLI support for Red Hat Enterprise Linux 6.1 (RHEL) is added.
Commmand Options added (unless stated otherwise) creatercopygroup -usr_cpg -snp_cpg createsv -noblock createvvcopy -online dismissrcopytarget -f dismissrcopyvv -keepsnap movepdtospare -vacate removeld -unused removercopygroup -removevv, -keepsnap setauthparam New specifier values: create-map, basic_edit-map, 3PAR_AO-map, 3PAR_RM-map sethost rst setnet addaddr, removeaddr, dns setrcopygroup cpg, -usr_cpg, -snp_cpg, -usr_cpg_unset, -snp_cpg_unset setsys New specifier values: RawSpaceAlert
Modifications to the OS CLI Issue ID Item Description 37356 IPv6 support has been added The CLI remote client now has the capability to connect to the HP 3PAR to the CLI client system with IPv6. 43691 The CLI Client can provide 1. The CLI client can provide the client application name, version and the name, version and host name host it runs from to the server.
Issue ID Item Description Role : super Connected since : 2010-08-10 11:31:13 PDT Current : current Client : remote Encrypted : N Client Name : myclient Client Host : envhost Client Version : 3.1 3. showuserconn default output has been modified to show the client name: cli% showuserconn Id Name ---IP_Addr--- -Role- ----Connected_since---Current Client ClientName 21283 root 192.168.80.57 super 2010-08-06 09:55:20 PDT - remote -21564 root 192.168.17.70 super 2010-08-06 10:35:40 PDT - remote -21598 root 192.
Issue ID Item Description run it. Exiting the command." In that case, the customer should run the command from a remote CLI session. 53041 tunepd may not be able to run in a SSH session If the system config is large, tunepd may not be able to run in the SSH session because of the memory limit. It will exit with the error message that there is not enough memory to run the command on the system. In that case, please run the command from the remote CLI client.
Issue ID Item Description 59715 sasl-mechanism set to GSSAPI and binding set to simple not functional. The combination of sasl-mechanism set to GSSAPI and binding set to simple does not function properly. 60105 servicecage syntax is incorrect. The servicecage command's specifier 0|1 is required for many subcommands including staretfc and endfc in order for the command to function properly. 63624 showport command displays incorrect error message.
3 HP 3PAR CIM API Release Notes What's new with HP 3PAR CIM API • 56532 - SMI-S support for StorageVolume with 16-byteWWN has been added. • 63950 - Support for SAS Initiator Ports Profile has been added. • 68741 - All customer alerts will be converted to generic AlertIndications, and a client can subscribe to TPD_AlertIndication to receive them.
Persona ClientTypes OtherClientTypeDescriptions 9 Other (1) Egenera 10 Other (1) NetApp/ONTAP 11 VMWare ESXi (19) ESX 4.x/5.x Removed and Deprecated Commands and Options • In Copy Services, SynchronizationType of UnSyncAssoc-Full has been removed.
Issue ID Item Description CleanCachePages, Write1CachePages, WriteNCachePages, WriteScheduledCachePages, WritingCachePages, PendingDelayedCooyOnWriteCachePages, ProcessingDelayedCopyOnWriteCachePages, FC10kRPMCfcDirty, FC15kRPMCfcDirty, NLCfcDirty, SSDCfcDirty, FC10kRPMCfcMax, FC15kRPMCfcMax, NLCfcMax, SSDCfcMax, FC10kRPMDelayedAck, FC15kRPMDelayedAck, NLDelayedAck, SSDDelayedAck, TotalCPUUserTimeCounter, TotalCPUSystemTimeCounter, TotalCPUIdleTimeCounter, Interrupts and ContextSwitches for TPD_NodeStatis
Issue ID Item Description CageInterfaceCard are added to CIM. NodePackage, PowerSupply & Battery providers change to support HP 3PAR components. 70904 Additional properties added to TPD_SFP The new properties added represent the threshold values for items Class. like temperature, voltage, transmit power, and receive power. These values are the same as the values displayed with the CLI command "showport -sfp -ddm".
Known Issues of the HP 3PAR OS CIM API Issue ID Item Description 81197 Detaching an RW snapshot of an RW When using StorageConfigurationService.ModifySynchronization volume will also cause the parent volume operation=Detach, or to be removed ReplicationService.ModifyReplicaSynchronization operation=Detach or operation="Return To Resource Pool" to remove an RW snapshot of an RW parent volume, the parent volume is also incorrectly being deleted.
4 HP 3PAR OS 3.1.2 MU1 Release Notes Online Upgrade Considerations This feature allows the upgrade of the OS concurrently with I/O activity on the attached hosts, provided certain conditions are met. For further information and pre-planning of online upgrades, refer to the latest version of the HP 3PAR OS Upgrade Pre-Planning Guide. To obtain a copy of this documentation, go to http://www.hp.com/3par/support_manuals, select your product, and then click Manuals. NOTE: Direct upgrades from 3.1.1.226 to 3.1.2.
Issue ID Item Description (VolSetAddr). When the Lun0SCC capability applies, LUN0 should not be used as a name for a storage LUN. 79816 EVA to 3PAR Online Migration tasks could fail if EVA to 3PAR Online Migration tasks could fail if the EVA the EVA is under load, and require restarting. is under load, and require restarting. Changes are made to improve the StoreServ's ability to deal with longer response times from the EVA during the importing phase. 80497 SCSI commands not terminating properly.
Issue ID Item Description self-correcting, but results in host delays, extraneous logging, and a temporary performance imbalance of some PDs. This issue is resolved and the source of missing interrupt is eliminated. 82123 The parsing of the manufacturing record on various FRU parts of the DCN1, DCS1, and DCS2 cages is not allowed. The parsing of the manufacturing record on various FRU parts of the DCN1, DCS1, and DCS2 cages is not allowed.
Issue ID Item Workaround multipathing solution be installed and configured on the HP-UX 11i v2 host. This will automatically retry IOs that timeout. 84066 During the process of upgrading the Service Processor (SP) to HP 3PAR OS 3.1.2 MU1 using SP-4.1.0.GA-60, if HP 3PAR OS version 3.1.2.322 (MU1) is installed on the SP before HP 3PAR OS 3.1.2.278 (GA) is installed on the SP, a warning message is displayed during installation. It is required that HP 3PAR OS 3.1.2.
5 HP 3PAR OS 3.1.2 MU2 Release Notes Online Upgrade Considerations This feature allows the upgrade of the OS concurrently with I/O activity on the attached hosts, provided certain conditions are met. For further information and pre-planning of online upgrades, refer to the latest version of the HP 3PAR OS Upgrade Pre-Planning Guide. To obtain a copy of this documentation, go to http://www.hp.com/3par/support_manuals, select your product, and then click Manuals. NOTE: Direct upgrades from 3.1.1.226 to 3.1.2.
New Supported Drives Drives StoreServ 400GB 7000, 7450, 10000, F-Class, T-Class 600GB 7000 1TB 7000 • 400GB Drives HP 3PAR StoreServ 7450 Storage System HP 3PAR OS 3.1.2 MU2 enables support for HP 3PAR StoreServ 7450 Storage system, a new all flash-array offering from the world’s most advanced storage platform. HP 3PAR StoreServ 7450 Storage delivers performance without compromises.
Remote Copy and Federated Technologies Enhancements • HP 3PAR Remote Copy Software in 1:N configuration is enhanced to provide synchronous mode replication support from source to both the target systems. • HP 3PAR Remote Copy Software is enhanced to support Four Link Connectivity in synchronous and periodic mode.
Issue ID Item 75161 CPG growth increments get set incorrectly when An issue is reported where CPG growth increments AO is running for SA and SD space is changed to invalid values on systems where AO is running. This issue is resolved. 77263 Issue resolved for RTPG SYSMGR event replay. This resolves a general protection fault in the SYSMGR event replay handling of a Remote Target Port Group (RTPG) command to LUN ID 0, which is not presented to the host initiator.
Issue ID Item Description 81540 HP 3PAR OS generates false "Cluster thermal shutdown" events. The electrical signal which indicates a severe thermal event is not handled properly, which sometimes results in false "Cluster thermal shutdown" event reports. This is resolved. 81685 SMI-S Provider initialization fails if an array has SMI-S provider fails if an array has an all-numeric an all-numeric name. name (the name as shown in showsys). This is resolved. 81901 Cage requests handling improved.
Issue ID Item Description includes a timeout. The HBA is supposed to return the request with an error code if it can not complete the request in the time specified by the driver. However, under certain circumstances, the HBA does not return the request within the time specified. This is resolved. A safety timer is added in the driver so that errors can be handled even if the HBA does not return the request within the time specified. 82492 Node cage battery firmware can be upgraded.
Issue ID Item 84307 Resolved licensing issue on post-ootb pre-license When HP 3PAR StoreServ 7000 Storage system install wipe. is not built to order it means that it is shipped with a license for 8 disks. If such a system goes through the ootb process to create the admin volume but the process is restarted before the actual license key is installed, it does not admit disks on the second attempt until the license key is removed manually. This is resolved. The disks can be admitted in this situation.
Issue ID Item Description while the system is powered-down, the alert still exists upon reboot. The alert is not cleared. 86957 Resolved AIX SCSI command timeouts on VV busy errors The SCSI subsystem is not handling busy errors from the Volume Layer correctly and it can result in SCSI commands being timed out for AIX (NACA supported) hosts. AIX issues an ABORT when the command timeout occurs and then retry the command.
6 HP 3PAR OS 3.1.2 MU2 CLI Release Notes What’s New in the OS CLI The following features are added for OS 3.1.2 MU2 CLI: • CLI client supports HP-UX 11iv3 for Integrity servers. • CLI client can run on Windows Server 2012 and SuSE 11. • New commands: controlencryption, setqos, setsnmpmgr, srstatqo, srstatlink, showqos, statqos Changed commands Commmand Options added (unless stated otherwise) addsnmpmgr -snmpuser, -version showalert -svc startao Acceptable time values expanded.
Issue ID Item Description showsnmpmgr command displays the version and user (if configured). The commands removeuser and removesnmpuser do not remove a user assigned to an SNMP manager. 82166 Add setsnmpmgr CLI command. The setsnmpmgr CLI command allows the user to change the properties associated with a previously configured SNMP manager. 82477 Reduce VM usage from long running tpdtcl processes.
7 HP 3PAR OS 3.1.2 MU2 CIM API Release Notes What's new with HP 3PAR CIM API • Added StorageVolume Lifecycle Indications for InstCreation, InstDeletion and InstModification of ElementName, NumberOfBlocks and OperationalStatus. • Added DynamicStoragePool Lifecycle Indications for InstCreation, InstDeletion and InstModification of RemainingManagedSpace. • Added support for FCoE port. A new class TPD_FCPortEthernetPortDependency is added which associates an FCoE TPD_FCPort with TPD_EthernetPort.
Issue ID Item Description 81685 SMI-S Provider initialization fails if array has an SMI-S provider fails if array has an all-numeric all-numeric name. name (the name as shown in showsys). This is resolved. 81925 Resolved an issue where calling Resolved an issue where calling HideLUsFromStorageHardwareIDCollection HideLUsFromStorageHardwareIDCollection results results in occasional "Invalid ProtocolControllers" in occasional "Invalid ProtocolControllers" failure. failure.
Issue ID Item Description due to the fact that ModifyInstance of SPC ElementName is not supported. This is resolved. 46 HP 3PAR OS 3.1.
8 HP 3PAR OS 3.1.2 MU2 SNMP Release Notes What's New with HP 3PAR SNMP • Added support for SNMPv3 trap. A user can specify the trap version (v2 or v3) for a particular SNMP manager. SNMPv3 traps are encrypted with CFB128-AES-128 and authenticated with HMAC-SHA-96 hash. What’s New in the OS CLI for SNMP The following is a new command in this release for SNMP: • setsnmpmgr - Change or assign a username to an SNMPv3 manager, or to convert a manager from v2 to v3 or from v3 to v2.
9 HP 3PAR OS 3.1.2 MU2 Web Services API Release Notes What's New with the HP 3PAR Web Services API Software • Support for Web Services API with HP 3PAR Operating System 3.1.2 MU2 HP 3PAR OS 3.1.2 MU2 WS API adds the following operations: 48 • Modification of Virtual Volume, Virtual Copies, CPG parameters. • Creation, Removal and modification of Hosts. • Query single item (as opposed to querying an entire collection). • Query Available Space. • Query General System Information. HP 3PAR OS 3.1.
10 HP 3PAR OS 3.1.2 EMU2 Release Notes Online Upgrade Considerations This feature allows the upgrade of the OS concurrently with I/O activity on the attached hosts, provided certain conditions are met. For further information and pre-planning of online upgrades, see the latest version of the HP 3PAR OS Upgrade Pre-Planning Guide. To obtain a copy of this documentation, go to http://www.hp.com/3par/support_manuals, select your product, and then click Manuals. NOTE: Direct upgrade from HP 3PAR OS 3.1.1.
Modifications to the HP 3PAR OS This release addresses the following items: 50 Issue ID Item 89348 Inquiry requests to LUN This addresses an issue of inquiry commands to the 3PAR vendor unique Vendor Unique Page timeout LUN page (0xC0h) timing out from hosts when upgrading from HP 3PAR when upgrading from HP OS 3.1.1 to HP 3PAR OS 3.1.2 or later. 3PAR OS 3.1.1 to HP 3PAR OS 3.1.2.
11 HP 3PAR OS 3.1.2 MU3 Release Notes Online Upgrade Considerations This feature allows the upgrade of the OS concurrently with I/O activity on the attached hosts, provided certain conditions are met. For further information and pre-planning of online upgrades, refer to the latest version of the HP 3PAR OS Upgrade Pre-Planning Guide. To obtain a copy of this documentation, go to http://h20566.www2.hp.com/portal/site/hpsc/public/psi/ manualsResults/?sp4ts.
Issue ID Item Description 78834 HP 3PAR 7200 storage system or HP 3PAR 7400 storage system Node Cage Battery alerts will not display null as the failure state. HP 3PAR 7200 storage system or HP 3PAR 7400 storage system Node Cage Battery alerts will not display null as the failure state. It will display the associated failure state such as not present, end of life, or not available. 79555 Cannot create VLUN on free port 1:2:1 in vlun_rand_create test. This is resolved.
Issue ID Item Description 88805 A subset of cage alerts continuously repeat. The following set of cage alerts repeat continuously, if any of the associate issues is present: • Cage temperature fault • Audible alarm fault • Display fault • Cage not supported fault • Bad link speed This is resolved. 88812 Improved handling of 7000 Series PCM Fans. Improved the handling of PCM Fans, as follows: 1. The processing of the fan tolerance warning is improved 2. The fan speed and ramp up are stabilized.
Issue ID Item Description upper-left PCM. This was in reverse order from the documentation. This is corrected such that PCM 0 is now reported for the upper-left PCM and PCM 1 for the lower-right PCM. 54 90386 Old port handle can cause SYSMGR to become unresponsive. Accessing the old port handles after a node reboot can cause the SYSMGR to become unresponsive. This is resolved by clearing the cached port handles. 90450 Check health speed is improved by not flagging PDs undergoing servicemag.
Issue ID Item Description 92724 The drives not behaving correctly keep bringing the The drives not behaving correctly keep bringing the entire loop up and down. entire loop up and down. The resolve this, bypass the misbehaving drives. When the link comes up, the driver issues PLOGIs to all devices in parallel. If the link goes down while some of the PLOGIs are still pending , then the driver issues PLOGIs to devices one by one.
12 HP 3PAR OS 3.1.2 MU4 Release Notes HP 3PAR OS 3.1.2 MU4 was not released. 56 HP 3PAR OS 3.1.
13 HP 3PAR OS 3.1.2 MU5 Release Notes Online Upgrade Considerations This feature allows the upgrade of the OS concurrently with I/O activity on the attached hosts, provided certain conditions are met. For further information and pre-planning of online upgrades, refer to the latest version of the HP 3PAR OS Upgrade Pre-Planning Guide. To obtain a copy of this documentation, go to http://h20566.www2.hp.com/portal/site/hpsc/public/psi/ manualsResults/?sp4ts.
Required order for upgrade and installation of software components IMPORTANT: Installing this version of OS requires that all affected software components in the storage environment be upgraded or installed in a specific order as detailed in the following list. Any listed host applications accessing the HP 3PAR storage system must be upgraded to the specified software levels in order for the storage environment to take full advantage of the new SSL certificate management functionality.
Table 1 Storage Replication Adapter for VMware Support Matrix SRA Site Replication Version Manager Version • 4 4.1.0 • 4.1 Hypervisor Versions Connectivity Protocols HP 3PAR Array Models HP 3PAR Operating System Versions • ESX / ESXi 4.0 Fibre Channel • HP 3PAR F-Class Storage 2.3.1 MU2 • HP 3PAR T-Class Storage • ESX / ESXi 4.1 • 3PAR S400,S800, E200 • HP 3PAR F-Class Storage 3.1.1 • HP 3PAR T-Class Storage • HP 3PAR StoreServ 10000 Storage • 5 5.1.1 • 5.1 • ESX / ESXi 4.
◦ 1.2 TB drive (HCEP1200S5xnN010) ◦ 480 GB (DOPA0480S5xnNMRI) and 920 GB (DOPA0920S5xnNMRI) drives • Reduces service times when running AO (Adaptive Optimization) or Tunesys. • Enhances the disk capacity of HP 3PAR StoreServ 7200 Storage array by increasing the maximum spindle count and the maximum raw capacity. • Provides support for failover via persistent ports of matched set VLUNs.
Issue ID Item Description 97582 Resolved LUN 0 HPUX inquiry failure during online This addresses an issue where an array does not upgrade. return a SCC (SCSI Controller Command) LUN inquiry data for LUN 0 for HP-UX hosts during online upgrades from HP 3PAR OS 3.1.2 MU1 or earlier. 97912 Under certain circumstances, a timer in the Fibre Under certain circumstances, a timer in the Fibre Channel driver triggers a port reset. This port reset Channel driver triggers a port reset.
14 Support and Other Resources Contacting HP For worldwide technical support information, see the HP support website: http://www.hp.
For information about: See: Migrating data from one HP 3PAR storage system to another HP 3PAR-to-3PAR Storage Peer Motion Guide Configuring the Secure Service Custodian server in order to monitor and control HP 3PAR storage systems HP 3PAR Secure Service Custodian Configuration Utility Reference Using the CLI to configure and manage HP 3PAR Remote Copy HP 3PAR Remote Copy Software User’s Guide Updating HP 3PAR operating systems HP 3PAR Upgrade Pre-Planning Guide Identifying storage system components
For information about: See: Planning for HP 3PAR storage system setup Hardware specifications, installation considerations, power requirements, networking options, and cabling information for HP 3PAR storage systems HP 3PAR 7200, 7400, and 7450 storage systems HP 3PAR StoreServ 7000 Storage Site Planning Manual HP 3PAR StoreServ 7450 Storage Site Planning Manual HP 3PAR 10000 storage systems HP 3PAR StoreServ 10000 Storage Physical Planning Manual HP 3PAR StoreServ 10000 Storage Third-Party Rack Physic
Typographic conventions Table 2 Document conventions Convention Element Bold text • Keys that you press • Text you typed into a GUI element, such as a text box • GUI elements that you click or select, such as menu items, buttons, and so on Monospace text • File and directory names • System output • Code • Commands, their arguments, and argument values • Code variables • Command variables Bold monospace text • Commands you enter into a command line interface • System