HP 3PAR Command Line Interface Reference (OS 3.1.2 MU2) (QL226-97016, June 2013)
clearlog
• For DC2 and DC4 drive cages, clear the log in the cage. FC-AL specifier is ignored.
• For DC3 drive cages, clearlog is not supported.
OPTIONS
–f
Forces the operation. When this option is not used, the command requires confirmation before
proceeding.
–ovrd
Forces the specified physical disk path offline even if it is the last remaining path.
SPECIFIERS
a|b
Specifies the side of the specified DC1 or DC3 drive cage to be serviced.
0|1
Specifies the side of the specified DC2 or DC4 drive cage to be serviced.
<cage_name>
Specifies the name of the drive cage to be serviced.
RESTRICTIONS
Access to all domains is required to run this command.
EXAMPLES
The following example displays the commencement of Fibre Channel hot-plugging for drive cage
cage0:
cli% servicecage startfc –f -ovrd cage0
NOTES
• Issuing the servicecage command results in chunklet relocation, causing a dip in throughput.
• The unstartfc subcommand is provided if a mistake was made when issuing the
servicecage command. The unstartfc subcommand stops the original command.
• After issuing the startfc or unstartfc subcommands, the endfc subcommand must be
issued to indicate that service is completed and to restore the drive cage to its normal state.
262 Service Commands