Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)
774 Fabric OS Message Reference
53-1002448-01
AN-1006
117
Recommended
Action
No action is required.
Severity INFO
AN-1006
Message <Sequence Number> AUDIT, <timestamp>, [AN-1006], INFO, FABRIC,
<event-initiator-details>, <event-location>, , Bottleneck detection configuration
is successfully changed.
Probable Cause Indicates that the bottleneck detection configuration was changed by a user.
Recommended
Action
No action is required.
Severity INFO
AN-1010
Message <Sequence Number> AUDIT, <timestamp>, [AN-1010], WARNING, FABRIC,
<event-initiator-details>, <event-location>, , Severe latency bottleneck detected
at Slot <slot number> port <port number within slot number>.
Probable Cause Indicates credit loss at the specified port, a downstream port, or a very high latency device at the
edge of the fabric.
Recommended
Action
Contact your vendor's customer support for assistance.
Severity WARNING
AN-1011
Message <Sequence Number> AUDIT, <timestamp>, [AN-1011], WARNING, FABRIC,
<event-initiator-details>, <event-location>, , Could not distinguish between
primary and dependent severe latency bottleneck on slot <slot number> port <port
number within slot number> because port mirroring is enabled on this port.
Probable Cause Indicates that resources needed to determine whether there is complete credit loss on a VC at this
port are in use by port mirroring.
Recommended
Action
Contact your vendor's customer support for assistance.
Severity WARNING