Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

606 Fabric OS Message Reference
53-1002448-01
SEC-1116
94
Recommended
Action
Run the secFabricShow command to verify that all switches in fabric are in the ready state. When
all switches are in the ready state, retry the operation.
Severity ERROR
SEC-1116
Message <timestamp>, [SEC-1116], <sequence-number>,, ERROR, <system-name>, Fail to commit
failover.
Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR
SEC-1117
Message <timestamp>, [SEC-1117], <sequence-number>,, INFO, <system-name>, Fail to set
<data>.
Probable Cause Indicates the switch failed to save the data received by the primary fabric configuration server
(FCS) switch. This data can be an FCS password, a non-FCS password, SNMP data, or multiple user
authentication data.
Recommended
Action
Run the secFabricShow command to verify that all switches in the fabric are in the ready state.
When all switches are in the ready state, retry the operation.
Severity INFO
SEC-1118
Message <timestamp>, [SEC-1118], <sequence-number>,, INFO, <system-name>, Fail to set
SNMP string.
Probable Cause Indicates the SNMP string could not be set.
Recommended
Action
Usually this problem is transient. Retry the command.
Severity INFO