Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)
400 Fabric OS Message Reference
53-1002448-01
FW-1429
45
Recommended
Action
Replace the missing power supply.
Severity WARNING
FW-1429
Message <timestamp>, [FW-1429], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor: Power supplies are not redundant.
Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the power supplies
are not in the correct slots for redundancy.
Recommended
Action
Rearrange the power supplies so that one is in an odd slot and other in an even slot to make them
redundant.
Severity WARNING
FW-1430
Message <timestamp>, [FW-1430], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor <string>.
Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty temperature sensors is greater than or equal to the policy set by the switchStatusPolicySet
command. A temperature sensor is faulty when the sensor value is not in the acceptable range or
is faulty.
Recommended
Action
Replace the field-replaceable unit (FRU) with the faulty temperature sensor.
Severity WARNING
FW-1431
Message <timestamp>, [FW-1431], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor Fan: <Number Bad> bad.
Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty fans is greater than or equal to the policy set by the switchStatusPolicySet command. A fan is
faulty when sensor value is not in the acceptable range or is faulty.
Recommended
Action
Replace the faulty or deteriorating fan field-replaceable units (FRUs).
Severity WARNING