FW-1004
45
Recommended
Action
This message generally appears when a fan fails. If so, a fan failure message accompanies this
message. Replace the fan field-replaceable unit (FRU).
Severity WARNING
FW-1004
Message <timestamp>, [FW-1004], <sequence-number>,, INFO, <system-name>, <Label>, is
between high and low boundaries(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause Indicates that the internal temperature of the switch has changed from a value outside of the
acceptable range to a value within the acceptable range.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation. If you receive a temperature-related message, check for an accompanying
fan-related message and check fan performance. If all fans are functioning normally, check the
climate control in your lab.
Severity INFO
FW-1009
Message <timestamp>, [FW-1009], <sequence-number>,, INFO, <system-name>, <Label>, value
has changed(High=<High value>, Low=<Low value>). Current value is <Value> <Unit>.
Probable Cause Indicates that the state of the power supply has changed from faulty to functional, or from
functional to faulty.
Recommended
Action
If the power supply is functioning correctly, no action is required.
If the power supply is functioning below the acceptable boundary, verify that it is seated correctly in
the chassis. Run the psShow command to view the status of the power supply. If the power supply
continues to be a problem, replace the faulty power supply.
Severity INFO
FW-1010
Message <timestamp>, [FW-1010], <sequence-number>,, WARNING, <system-name>, <Label>, is
below low boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause Indicates that the power supply is faulty. The power supply is not producing enough power.
Recommended
Action
Verify that you have installed the power supply correctly and that it is correctly seated in the
chassis. If the problem persists, replace the faulty power supply.
Severity WARNING