Fault Symptom Codes (FSC)
Fault Symptom Codes (FSCs) are in the Fault Screen described in Chapter 2.
Each FSC is accompanied by a descriptive message and instructions for
clearing the fault. When a fault persists, the operator should look up the FSC
in Table 6-2 to determine the error recovery procedure to be followed. If you
call Compaq Technical Support about a fault condition, be sure to furnish the
FSC to aid in identifying the problem.
Table 6-2
Fault Symptom Codes
System Error Codes 0xxx
FSC Message Description
0101
Unused Interrupt An undefined interrupt occurred.
0102 Enqueue’g a Null Ptr
A NULL pointer was passed to one of
the enqueing functions. This is
generally a firmware bug.
0103
Invalid Cmd Rec’d An illegal trace command was
received by the trace process.
0201 Trc Comm Open Error
The trace port could not be opened.
0301 Novram Init Error
A failure occurred when trying to
initialize the Novram.
0302 Novram Chksum Error
A checksum error was detected while
reading the Novram.
0303 Novram Program Error
A problem was detected while trying
to update the Novram.
0304 Novram Downld Error
An error was detected while trying to
download configuration data.
0305 Novram Data Error
An error was detected while trying to
validate the Novram.
0306 Novram Update Error
A problem was detected while trying
to update the Novram.
continued