Configuration 4-5
To operate the TL881 in Sequential Mode, the following configuration
parameters must be established:
Library Mode- change from Random (default) to Sequential DLT0
Sequential Mode must remain at Normal (default)
Test Unit Ready (TUR) - must remain at Custom (default)
To establish these parameters for Sequential Mode operation, proceed as
follows:
1. From the Default Menu press
Enter. The Main Menu shown in Figure 4-
6 appears:
SHR-1331
Figure 4-6. Main Menu
2. Press three times so that the is next to Configure Menu and press
Enter. The Configure Submenu shown in Figure 4-7 appears:
SHR-1332
Figure 4-7. Configure Submenu
3. Press twice so that the is next to Set Library Mode and press
Enter. The Library Mode Selection Menu shown in Figure 4-8 appears:
SHR-1461
Figure 4-8. Library Mode Selection Menu
4. Press Enter again so the is next to *Random.