Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide (July 2000)

Diagnostics and Troubleshooting 6-9
Compaq Confidential – Need to Know Required
Writer:
Bob Young
Project:
Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide
Comments:
Part Number:
127510-002
File Name:
g-ch6 Diagnostics and Troubleshooting.doc
Last Saved On:
7/12/00 11:32 AM
Table 6-4
Control Error Codes (2xxx)
continued
FSC Message Description
2030 DLT Timeout Error During power up, communication with one of the
DLT drives was unsuccessful.
2031 DLT Timeout Error While trying to update the front panel,
communication with one of the DLT drives was
unsuccessful.
2032 DLT Timeout Error Communication with DLT drive 0 was unsuccessful
(sequential mode).
2033 DLT Timeout Error Communication with DLT drive 1 was unsuccessful
(sequential mode).
2034 DLT Timeout Error While attempting to update the cartridge map,
communication with one of the DLT drives was
unsuccessful.
204x Invalid Ctl Msg An illegal message type code was received. This
can be the result of receiving a NULL type code, a
status code without a command being active, or a
command code while a command is currently active.
205x No Free Queues The system could not allocate a free queue.
206x Calib. Error Port x When trying to locate the unit attached to port x, the
pass-through elevator reached the top of rail.
206f Pass-thru Init Error The pass-through elevator did not travel a minimum
distance to reach the top of its travel.
2070 Command Timeout Enter to reboot. The 10 minute timer was exceeded
when trying to fetch from a drive.
2071 Command Timeout Internal error only. Not reported to the operator or
host.
2072 Command Timeout Power down, Wait 30 seconds, Power up. Occurs if
the power is cycled too quickly and the DLT drive
comes up in an error state and doesn’t communicate
with the MiniLibrary system controller.
continued