HP Scitex FB910, Legacy UV, Designjet H and Legacy Solvent Printer Series - Vacuum Pressure System Guide for Operators

Filters
While the blue “cup” is not a lter, there are several air lters used on the VP system. These disk-shaped lters are
about 1” (2.5cm) in diameter. One lter is found in-line on the long vacuum tube. The remaining lters (2 of them)
are inside the V/P assembly, underneath the metal enclosure.
Printers that are in unusually dusty or other environments with many airborne particles will need to have these lters
replaced regularly. Filter kit 0901421 includes three lters with ttings and replacement instructions.
Setting and Adjusting the Vacuum Level
The V/P assembly has a regulator to adjust the amount of vacuum applied against the printheads. For solvent print-
ers, the nominal vacuum level should be 3.25 inches of water. For UV printers, the nominal vacuum level should
be 5.00 inches of water. Note that for both printer types this gure is different than the number speci ed in the
respective printer’s User Manual. A variation of ±0.20 from the nominal value is normal and acceptable.The printer
software is programmed to know what the correct vacuum settings is and will show a Warning if the actual vacuum
is too high or too low.
If you do encounter a warning, or if you simply observe that the vacuum level has changed, you can easily adjust it
back into the desired range. You will need a regular at-bladed screwdriver to make the adjustment.
On the ColorSpan Legacy Solvent and UVR-UVX printers, the regulator is located on the back of the printer, on the
VP assembly, shown below.
Two views of the air filters used in the Vacuum/Pressure assembly.
On the left is the in-line filter, removed from the vacuum line.
On the right is the input filter inside of the V/P assembly. Not visible
is another filter on the vacuum regulator. All of the filters have the same
specification.
4