3-34 Media Wizard
Heater temps setting (for the post-heater/dryer) (roll
fed) — select a heater setting from 0 to 10, or Custom to
specify custom settings. Setting 0 sets all heaters to 8
F (30° C).
The preheater and platen heater maintain uniform sur-
face temperature across the printing area to control dot
gain on various media. The postheater dries prints before
being rolled onto the take-up spool. If prints are not dry-
ing, increase the postheater temperature; if media is
deforming or sticking to the postheater, lower or turn off
the postheater.
Platen vacuum fans — this option turns on the vacuum
fans, and displays , and ) keys on the control panel.
Press , and ) to raise or lower the fan speed, and
observe the media as the fan speed changes. If the
media is lifting off the platen, increase the fan speed. If
the media is sticking to the platen, decrease the fan
speed.
Drying delay — press the , and ) keys on the control
panel to increase or decrease the drying delay (seconds
per print swath). To increase throughput, decrease the
drying delay. If prints are not drying, increase the dry-
ing delay.
3. When you select Create Media Type, the Media Wizard dis-
plays a series of screens that enable you to enter each of the
Media Wizard settings.
The current settings as shown on the Media Settings screen
are used as default values. Change the defaults to suit the
new media for each print mode.
4. When you select Delete Media Type, the Media Wizard
shows a list of currently defined media. You can delete any
user-defined media type.
5. When you select View Media Types, the Media Wizard
allows you to browse through the settings for each of the
media types and print modes.