DisplayMaker Legacy X-12+ - User Manual

Manual Calibrations 4-15
Clear all bad jets — clears (marks as good) all jets cur-
rently marked as unusable.
Select an option and follow the corresponding procedure
below.
Report Individual Bad Jets
When you select Report Individual Bad Jets, the control
panel displays the following prompt:
Head 1:
Press Proceed to report a bad jet.
8. Press C and p to select a head number, then press B
(Proceed).
The control panel displays a numeric keyboard that you can
use to enter the number of the bad jet.
9. Enter the jet number, then press the Enter key.
10. When you are finished entering jet numbers, press the Esc
key.
The control panel displays the head selection message again.
11. Press C and p to select the next head number, then press B
(Proceed).
12. Repeat steps 9 through 11 for each head containing bad jets
you want to report.
Fig. 4-21. Numeric entry screen