DisplayMaker Legacy 72SI and 98SI - User Manual

Calibrate the Service Station 5-17
Calibrate the Service
Station
Service station calibration enables you to properly align the ser-
vice station wipers to the printheads. When properly aligned,
the service station wipers should be centered on the printheads.
Setting the service station height should not be necessary unless
the printhead height is changed by a large amount, or you
notice that the service station wipers are not wiping the print-
heads adequately.
1. On the Front Page screen, press the (Menu) key to enter
the menu system.
2. Press the ) key repeatedly to highlight Service Printer.
3. Press the (Menu In) key display the Service Printer menu.
4. Press the ) key repeatedly to highlight Service Station.
5. Press the (Menu In) key.
The control panel prompts you to confirm that you want to
calibrate the service station.
Fig. 5-6. Service station (cover removed for clarity)
Adjustment screws
Wipers
Printheads
Look here to calibrate