DisplayMaker Legacy 72UVX and 98UVX - User Manual

Table Of Contents
Menu 2-11
Manual Calibrations — allows you to calibrate the printer
visually, without the printer’s digital imaging sensor. Inaccu-
rate judgments by the operator during these tests could
result in substandard output. See “Manual Calibrations” on
page 4-8 for instructions.
Media Feed
Manual Bidi Registration
Manual X Head Registration
Manual Jet Mapping — the manual version of AutoJet
Jet Status Lines — prints the Manual Jet Mapping pat-
tern without running the calibration
Print Jet-Out Lines — prints a version of the prime bars
(see page page 2-6), in which missing jets that are
replaced are marked with a black square.
Default Registration Data
AutoTune (roll-fed media only) — schedules jet maintenance
to run automatically after a certain number of prints have
printed. See “AutoTune” on page 4-4 for instructions.
Calibration Summary prints summary information with
the AutoSet calibration test patterns, or transmits registra-
tion or jet data to a log file on the print server. See “Calibra-
tion Summary” on page 4-25 for details.
Configure for Profile Creation (cut sheet printing only) —
causes all calibration prints to print on the same cut sheet,
rather than ejecting the sheet after each calibration print.
Automatically disabled after all calibration prints are fin-
ished, when a print job is received from the RIP, or when roll-
fed media is loaded. The user can specify a dry time delay
after which the linearization will begin.
Printer Settings Printer Settings enables you to set many options that control
how the printer operates. Settings saved by the Media Wizard are
indicated by
MEDIA WIZARD in the margin.
MEDIA WIZARD Takeup Tension — adjusts the media takeup tension, which
is required for proper media feeding. Insufficient takeup ten-
sion could result in inaccurate media feed and media buck-
ling.
MEDIA WIZARD Supply Tension (72UVX) — adjusts the media supply ten-
sion, which is required for proper media feeding. The lowest
(“idle”) tension is best for most media. (The 98
UVX supply
tension is always idle.)