Cisco Nexus 5000 Series Switch Fabric Manager Software Configuration Guide, NX-OS 4.0 (OL-16598-01, June 2008)

Send comments to nx5000-docfeedback@cisco.com
15-10
Nexus 5000 Series Switch Fabric Manager Software Configuration Guide
OL-16598-01
Chapter 15 Configuring and Managing VSANs
Configuring VSANs
Figure 15-6 VSAN Port Membership Details
VSAN-based runtime (name server), zoning, and configuration (static routes) information is
removed when the VSAN is deleted.
Configured VSAN interface information is removed when the VSAN is deleted.
Note The allowed VSAN list is not affected when a VSAN is deleted (see Chapter 13, “Configuring VSAN
Trunking”).
Any commands for a nonconfigured VSAN are rejected. For example, if VSAN 10 is not configured in
the system, then a command request to move a port to VSAN 10 is rejected.
Deleting Static VSANs
To delete a VSAN and its attributes using Fabric Manager, perform this task:
Step 1 Click All VSANs from the Logical Domains pane.
The VSANs in the fabric are listed in the Information pane.
Step 2 Right-click the VSAN that you want to delete and click Delete Row from the drop-down menu (see
Figure 15-7).
Default
VSAN
fc1/1
fc1/2
VSAN 7
fc1/3
fc1/4
Isolated
VSAN
VSAN 12
fc1/5
fc1/6
Before
Default
VSAN
fc1/1
fc1/2
VSAN 7
fc1/3
fc1/4
Isolated
VSAN
fc1/5
fc1/6
VSAN 12
fc1/5
fc1/6
After
Switch 1 Switch 1
79947