Cisco Nexus 5000 Series Switch Fabric Manager Software Configuration Guide, NX-OS 4.0 (OL-16598-01, June 2008)
Send comments to nx5000-docfeedback@cisco.com
11-19
Nexus 5000 Series Switch Fabric Manager Software Configuration Guide
OL-16598-01
Chapter 11 Configuring Domain Parameters
FC IDs
Step 6 Check the Enable check box to enable the persistent FC ID feature in the switch (see Figure 11-13).
Step 7 Click the Persistent FcIds tab and assign a new FC ID with a different area allocation in the FcId field.
For example, in Figure 11-13 we replace 00 with ee.
Figure 11-13 Setting the FC ID in Fabric Manager
Step 8
Click Apply Changes to save the new FC ID.
Step 9 Compare the FC ID values to verify the FC ID of the HBA.
Note Both FC IDs now have different area assignments.
Step 10 In the Physical Attributes pane, eXpand Switches > Interfaces, and then choose FC Physical. Set the
Status Admin drop-down list to up for the interface that the HBA is connected to.
This enables the HBA interface in the Nexus 5000 Series switch.
About Persistent FC ID Selective Purging
Persistent FC IDs can be purged selectively. Static entries and FC IDs currently in use cannot be deleted.
Table 11-1 identifies the FC ID entries that are deleted or retained when persistent FC IDs are purged.
Purging Persistent FC IDs
To purge persistent FC IDs using Fabric Manager, perform this task:
Table 11-1 Purged FC IDs
Persistent FC ID state Persistent Usage State Action
Static In use Not deleted
Static Not in use Not deleted
Dynamic In use Not deleted
Dynamic Not in use Deleted