Brocade iSCSI Gateway Service Administrator's Guide (53-1000603-01, October 2007)

iSCSI Gateway Service Administrator’s Guide 13
53-1000603-01
Enabling the iSCSI gateway service
2
Enabling the iSCSI gateway service
The iSCSI gateway service translates and directs SCSI traffic between an iSCSI initiator and an
FC target. This section explains how to enable the iSCSI gateway service on the Brocade 48000.
To enable the iSCSI gateway service
1. Connect and log in to the switch.
2. Enter the following command to show the current Fabric OS configuration.
switch:admin> fosconfig --show
FC Routing service:disabled
iSCSI service:disabled
iSNS Client service: disabled
3. Enter the following command to enable the iSCSI gateway service.
switch:admin> fosconfig --enable iscsi
iSCSI service is enabled
4. Verify that the iSCSI gateway service is enabled.
switch:admin> fosconfig --show
FC Routing service:disabled
iSCSI service:enabled
iSNS Client service:disabled
Enabling the GbE interface
Enable the physical GbE ports. Before enabling the physical iSCSI interface, enable the iSCSI
gateway service as described in “Enabling the iSCSI gateway service” on page 13.
By default, GbE ports are enabled on an FC4-16IP blade installed in the Brocade 48000. However,
if you insert the FC4-16IP blade into a slot that was previously occupied by an FR-18i blade, GbE
ports are disabled.
NOTE
The GbE port number <port_number> below is entered geX; where X is from 0 through 7.
For example ge1 (see Figure 8 on page 12).