Brocade Fabric OS Message Reference Supporting Fabric OS v6.0.0 (53-1000600-01, October 2007)
Fabric OS Message Reference 245
53-1000600-01
FW-1444
29
FW-1444
Message <timestamp>, [FW-1444], <sequence-number>,, WARNING, <system-name>, <FRU label>
state has changed to <FRU state>.
Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to “faulty”.
Recommended
Action
Replace the FRU.
Severity WARNING
FW-1445
Message <timestamp>, [FW-1445], <sequence-number>,, INFO, <system-name>, Four power
supplies are now required for 2X redundancy, Switch Status Policy values changed.
Probable Cause Indicates that the switch now requires 4 power supplies and previous Switch Status Policy
parameters will be overwritten to reflect this. The presence of an AP blade means that more than
one power supply may be required to provide adequate power. So (even if the AP blade is powered
down or removed) the Switch Status policy values will now reflect the need for 4 power supplies to
maintain full (2X) redundancy.
Recommended
Action
No action required, unless there are fewer than 4 power supplies active in the chassis. If there are
fewer than 4, insert additional power supplies so that there are 4 active.
Severity INFO
FW-1446
Message <timestamp>, [FW-1446], <sequence-number>,, WARNING, <system-name>, Four power
supplies now required for 2X redundancy, not enforced by Fabric Watch due to
Switch Status Policy overridden by User.
Probable Cause Indicates that the switch now requires 4 power supplies for full (2X) redundancy, but the user has
previously overridden the Switch Status Policy values pertaining to number of power supplies. So
those values will not be automatically changed. The default values with no AP blades are: 3 out of
service indicates switch status is DOWN, 0 indicates no checking for switch status MARGINAL. The
default values when an AP blade is or has been present are: 2 out of service indicates switch
status is DOWN, 1 out of service indicates switch status is MARGINAL
Recommended
Action
To maintain full (2X) redundancy and proper monitoring by Fabric Watch, 4 active power supplies
should be supplied and the default values associated with the presence of an AP blade should be
entered with switchStatusPolicyset.
Severity WARNING